Сензори за налягане

Pressure Sensors

3216 продукта · стр. 91/134

PFT-FAB4X0AF2OHCALSSZ
6050744

PFT-FAB4X0AF2OHCALSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0AF2OHCALSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FAB4X0AF2OHCAMSSZ
6069617

PFT-FAB4X0AF2OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0AF2OHCAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FAB4X0AF2OHCVMSSZ
6068664

PFT-FAB4X0AF2OHCVMSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0AF2OHCVMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-FAB4X0AF2OSSALSSZ
6050850

PFT-FAB4X0AF2OSSALSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0AF2OSSALSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FAB4X0AF2OSSAMSSZ
6047991

PFT-FAB4X0AF2OSSAMSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0AF2OSSAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FAB4X0SF2OHCAMSSZ
6069641

PFT-FAB4X0SF2OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0SF2OHCAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FAB4X0SF2OSSAMSSZ
6042102

PFT-FAB4X0SF2OSSAMSSZ

SICK

Pressure sensors | PFT | PFT-FAB4X0SF2OSSAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure por

PFT-FAB6X0SF2OSSUMSSZ
6081052

PFT-FAB6X0SF2OSSUMSSZ

SICK

Pressure sensors | PFT | PFT-FAB6X0SF2OSSUMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 6 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FABX25SF1OHCAMSSZ
6062631

PFT-FABX25SF1OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FABX25SF1OHCAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G 1 B flush-mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FCA100SF1OHCALSSZ
6044562

PFT-FCA100SF1OHCALSSZ

SICK

Pressure sensors | PFT | PFT-FCA100SF1OHCALSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –100 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressu

PFT-FCA100SF1OSSAMSSZ
6042609

PFT-FCA100SF1OSSAMSSZ

SICK

Pressure sensors | PFT | PFT-FCA100SF1OSSAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –100 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressu

PFT-FCA100SF1OSSVMSSZ
6065029

PFT-FCA100SF1OSSVMSSZ

SICK

Pressure sensors | PFT | PFT-FCA100SF1OSSVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –100 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G 1 B flush-mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-FCA250SF1OSCVMSSZ
6051695

PFT-FCA250SF1OSCVMSSZ

SICK

Pressure sensors | PFT | PFT-FCA250SF1OSCVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressu

PFT-FCB010AF2OHCALSSZ
6075140

PFT-FCB010AF2OHCALSSZ

SICK

Pressure sensors | PFT | PFT-FCB010AF2OHCALSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 10 V DC ... 30 V DC

PFT-FCB010AF2OHCAMSSZ
6052048

PFT-FCB010AF2OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010AF2OHCAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure p

PFT-FCB010AF2OSCAMSSZ
6064463

PFT-FCB010AF2OSCAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010AF2OSCAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FCB010AF2OSSVMSSZ
6083677

PFT-FCB010AF2OSSVMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010AF2OSSVMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure p

PFT-FCB010SF2OHCALSSZ
6050022

PFT-FCB010SF2OHCALSSZ

SICK

Pressure sensors | PFT | PFT-FCB010SF2OHCALSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FCB010SF2OHCAMSSZ
6049563

PFT-FCB010SF2OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010SF2OHCAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FCB010SF2OSCALSSZ
6050023

PFT-FCB010SF2OSCALSSZ

SICK

Pressure sensors | PFT | PFT-FCB010SF2OSCALSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FCB010SF2OSCAMSSZ
6065032

PFT-FCB010SF2OSCAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010SF2OSCAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FCB010SF2OSSAMSSZ
6071966

PFT-FCB010SF2OSSAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB010SF2OSSAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-FCB016SF2OSSAMSSZ
6051031

PFT-FCB016SF2OSSAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB016SF2OSSAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure p

PFT-FCB025SF2OHCAMSSZ
6067363

PFT-FCB025SF2OHCAMSSZ

SICK

Pressure sensors | PFT | PFT-FCB025SF2OHCAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 24 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC