Сензори за дебит

Flow Sensors

83 продукта · стр. 4/4

FTS-I061F14A
1114951

FTS-I061F14A

SICK

Flow sensors | T-Easic FTS | FTS-I061F14A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connecto

FTS-I061F14B
1114952

FTS-I061F14B

SICK

Flow sensors | T-Easic FTS | FTS-I061F14B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25),

FTS-I100F14A
1091144

FTS-I100F14A

SICK

Flow sensors | T-Easic FTS | FTS-I100F14A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-I100F14B
1114230

FTS-I100F14B

SICK

Flow sensors | T-Easic FTS | FTS-I100F14B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-

FTS-I101F14A
1114953

FTS-I101F14A

SICK

Flow sensors | T-Easic FTS | FTS-I101F14A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connecto

FTS-I101F14B
1114954

FTS-I101F14B

SICK

Flow sensors | T-Easic FTS | FTS-I101F14B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25),

FTS-I200F14A
1091145

FTS-I200F14A

SICK

Flow sensors | T-Easic FTS | FTS-I200F14A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-I200F14B
1114231

FTS-I200F14B

SICK

Flow sensors | T-Easic FTS | FTS-I200F14B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-

LMS111-10190
1093274

LMS111-10190

SICK

Flow sensors | Bulkscan | LMS111-10190 | Output signal: Ethernet, Digital inputs and digital outputs, USB auxiliary interface, RS-232/RS-422 | Connection type: M12 round connector | Communication interface: Serial, USB | Display: no | Laser class: 1, eye-safe (IEC 60825-1:2014) | Working range: 0.5 m ... 10 m | Switching outputs: 3 | Supply voltage scanner/heater: 10.8 V ... 30 V | Enclosure rating: IP67 | Calibration certificate: no

LMS511-20190
1059529

LMS511-20190

SICK

Flow sensors | Bulkscan | LMS511-20190 | Output signal: Ethernet, Digital inputs and digital outputs, USB auxiliary interface, RS-232/RS-422 | Connection type: M12 round connector | Communication interface: Serial, USB | Display: no | Laser class: 1, eye-safe (IEC 60825-1:2014) | Working range: 0.5 m ... 20 m | Switching outputs: 6 | Supply voltage scanner/heater: 19.2 V ... 28.8 V | Enclosure rating: IP67 | Calibration certificate: no

MOLOSflow FSM51

MOLOSflow FSM51

Mollet

The MOLOSflow FSM flow monitor detects faults in the transportation of bulk solids in pipelines, on conveyor belts, on drop plates, on chutes, behind screws or in similar conveyor systems at an early stage. It ensures that the transportation of powders, dusts, pellets and granulates runs smoothly and thus prevents system failures.