Сензори за дебит

Flow Sensors

83 продукта · стр. 2/4

FFUS10-1N1IO
6047868

FFUS10-1N1IO

SICK

Flow sensors | FFU | FFUS10-1N1IO | Nominal width measuring tube: DN 10 | Maximum flow: ≤ 21 l/min | Wetted parts: PPSU, EPDM | Process connection: ½" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS10-1N1SR
6050786

FFUS10-1N1SR

SICK

Flow sensors | FFU | FFUS10-1N1SR | Nominal width measuring tube: DN 10 | Maximum flow: ≤ 21 l/min | Wetted parts: PPSU, EPDM | Process connection: ½" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1C1IO
6045162

FFUS15-1C1IO

SICK

Flow sensors | FFU | FFUS15-1C1IO | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1C1SR
6066449

FFUS15-1C1SR

SICK

Flow sensors | FFU | FFUS15-1C1SR | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1G1IO
6041249

FFUS15-1G1IO

SICK

Flow sensors | FFU | FFUS15-1G1IO | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: G ¾ | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1G1SR
6043744

FFUS15-1G1SR

SICK

Flow sensors | FFU | FFUS15-1G1SR | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: G ¾ | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1N1IO
6047869

FFUS15-1N1IO

SICK

Flow sensors | FFU | FFUS15-1N1IO | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: ¾" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS15-1N1SR
6060235

FFUS15-1N1SR

SICK

Flow sensors | FFU | FFUS15-1N1SR | Nominal width measuring tube: DN 15 | Maximum flow: ≤ 36 l/min | Wetted parts: PPSU, EPDM | Process connection: ¾" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 16 bar

FFUS20-1C1IO
6049061

FFUS20-1C1IO

SICK

Flow sensors | FFU | FFUS20-1C1IO | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS20-1C1SR
6059009

FFUS20-1C1SR

SICK

Flow sensors | FFU | FFUS20-1C1SR | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS20-1G1IO
6041738

FFUS20-1G1IO

SICK

Flow sensors | FFU | FFUS20-1G1IO | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: G 1 | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS20-1G1SR
6043745

FFUS20-1G1SR

SICK

Flow sensors | FFU | FFUS20-1G1SR | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: G 1 | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS20-1N1IO
6047870

FFUS20-1N1IO

SICK

Flow sensors | FFU | FFUS20-1N1IO | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: 1" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS20-1N1SR
6058219

FFUS20-1N1SR

SICK

Flow sensors | FFU | FFUS20-1N1SR | Nominal width measuring tube: DN 20 | Maximum flow: ≤ 60 l/min | Wetted parts: PPSU, EPDM | Process connection: 1" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1C1IO
6044523

FFUS25-1C1IO

SICK

Flow sensors | FFU | FFUS25-1C1IO | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1C1SR
6052255

FFUS25-1C1SR

SICK

Flow sensors | FFU | FFUS25-1C1SR | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: Clamp (DIN 11864-3) | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1G1IO
6041739

FFUS25-1G1IO

SICK

Flow sensors | FFU | FFUS25-1G1IO | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: G 1 ¼ | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1G1SR
6043746

FFUS25-1G1SR

SICK

Flow sensors | FFU | FFUS25-1G1SR | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: G 1 ¼ | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1N1IO
6044996

FFUS25-1N1IO

SICK

Flow sensors | FFU | FFUS25-1N1IO | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: 1 ¼" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FFUS25-1N1SR
6049566

FFUS25-1N1SR

SICK

Flow sensors | FFU | FFUS25-1N1SR | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: 1 ¼" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

FTMG-ESD08AXX
1143755

FTMG-ESD08AXX

SICK

Flow sensors | FTMg | FTMG-ESD08AXX | Nominal width measuring tube: DN 08 | Process connection: G ¼ (according to DIN ISO 228-1) | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESD15AXX
1100214

FTMG-ESD15AXX

SICK

Flow sensors | FTMg | FTMG-ESD15AXX | Nominal width measuring tube: DN 15 | Process connection: G ½ (according to DIN ISO 228-1) | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESD20AXX
1100215

FTMG-ESD20AXX

SICK

Flow sensors | FTMg | FTMG-ESD20AXX | Nominal width measuring tube: DN 20 | Process connection: G ¾ (according to DIN ISO 228-1) | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESD25AXX
1100216

FTMG-ESD25AXX

SICK

Flow sensors | FTMg | FTMG-ESD25AXX | Nominal width measuring tube: DN 25 | Process connection: G 1 (according to DIN ISO 228-1) | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no