Сензори за дебит

Flow Sensors

83 продукта · стр. 3/4

FTMG-ESN40SXX
1122524

FTMG-ESN40SXX

SICK

Flow sensors | FTMg | FTMG-ESN40SXX | Nominal width measuring tube: DN 40 | Process connection: 1 1/2” NPT male thread | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESN50SXX
1122526

FTMG-ESN50SXX

SICK

Flow sensors | FTMg | FTMG-ESN50SXX | Nominal width measuring tube: DN 50 | Process connection: 2” NPT male thread | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESR40SXX
1120114

FTMG-ESR40SXX

SICK

Flow sensors | FTMg | FTMG-ESR40SXX | Nominal width measuring tube: DN 40 | Process connection: R 1 ½ male thread | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ESR50SXX
1120116

FTMG-ESR50SXX

SICK

Flow sensors | FTMg | FTMG-ESR50SXX | Nominal width measuring tube: DN 50 | Process connection: R 2 male thread | Output signal: OPC UA, MQTT, integrated web server, REST API | Connection type: 1 x M12 round connector, 8-pin, X-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communication interface: MQTT | Process temperature: –20 °C ... +60 °C | Display: yes | Enclosure rating: IP65, IP67 | Calibration certificate: no

FTMG-ISD08AXX
1143754

FTMG-ISD08AXX

SICK

Flow sensors | FTMg | FTMG-ISD08AXX | Nominal width measuring tube: DN 08 | Process connection: G ¼ (according to DIN ISO 228-1) | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.43

FTMG-ISD15AXX
1100211

FTMG-ISD15AXX

SICK

Flow sensors | FTMg | FTMG-ISD15AXX | Nominal width measuring tube: DN 15 | Process connection: G ½ (according to DIN ISO 228-1) | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.43

FTMG-ISD20AXX
1100212

FTMG-ISD20AXX

SICK

Flow sensors | FTMg | FTMG-ISD20AXX | Nominal width measuring tube: DN 20 | Process connection: G ¾ (according to DIN ISO 228-1) | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.43

FTMG-ISD25AXX
1100213

FTMG-ISD25AXX

SICK

Flow sensors | FTMg | FTMG-ISD25AXX | Nominal width measuring tube: DN 25 | Process connection: G 1 (according to DIN ISO 228-1) | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.43

FTMG-ISN40SXX
1122523

FTMG-ISN40SXX

SICK

Flow sensors | FTMg | FTMG-ISN40SXX | Nominal width measuring tube: DN 40 | Process connection: 1 1/2” NPT male thread | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Commu

FTMG-ISN50SXX
1122525

FTMG-ISN50SXX

SICK

Flow sensors | FTMg | FTMG-ISN50SXX | Nominal width measuring tube: DN 50 | Process connection: 2” NPT male thread | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communica

FTMG-ISR40SXX
1120053

FTMG-ISR40SXX

SICK

Flow sensors | FTMg | FTMG-ISR40SXX | Nominal width measuring tube: DN 40 | Process connection: R 1 ½ male thread | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communicat

FTMG-ISR50SXX
1120115

FTMG-ISR50SXX

SICK

Flow sensors | FTMg | FTMG-ISR50SXX | Nominal width measuring tube: DN 50 | Process connection: R 2 male thread | Output signal: 1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud) | Connection type: M12 x 1 round connector, 5-pin, A-coded | Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301 | Communicatio

FTS-H060F04A
1091149

FTS-H060F04A

SICK

Flow sensors | T-Easic FTS | FTS-H060F04A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-H060F04B
1114235

FTS-H060F04B

SICK

Flow sensors | T-Easic FTS | FTS-H060F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-

FTS-H061F04A
1114955

FTS-H061F04A

SICK

Flow sensors | T-Easic FTS | FTS-H061F04A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connecto

FTS-H061F04B
1114956

FTS-H061F04B

SICK

Flow sensors | T-Easic FTS | FTS-H061F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25),

FTS-H100F04A
1091147

FTS-H100F04A

SICK

Flow sensors | T-Easic FTS | FTS-H100F04A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-H100F04B
1114233

FTS-H100F04B

SICK

Flow sensors | T-Easic FTS | FTS-H100F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-

FTS-H101F04A
1114957

FTS-H101F04A

SICK

Flow sensors | T-Easic FTS | FTS-H101F04A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connecto

FTS-H101F04B
1114958

FTS-H101F04B

SICK

Flow sensors | T-Easic FTS | FTS-H101F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25),

FTS-H200F04A
1091148

FTS-H200F04A

SICK

Flow sensors | T-Easic FTS | FTS-H200F04A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-H200F04B
1114234

FTS-H200F04B

SICK

Flow sensors | T-Easic FTS | FTS-H200F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-

FTS-I060F14A
1091146

FTS-I060F14A

SICK

Flow sensors | T-Easic FTS | FTS-I060F14A | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (wit

FTS-I060F14B
1114232

FTS-I060F14B

SICK

Flow sensors | T-Easic FTS | FTS-I060F14B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Without process connection (adapter needed for installation) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-