Сензори за налягане
Pressure Sensors
3216 продукта · стр. 56/134

PBT-RB040SG2SS0VLC0Z
Pressure sensors | PBT | PBT-RB040SG2SS0VLC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connect

PBT-RB040SG2SS0VMC0Z
Pressure sensors | PBT | PBT-RB040SG2SS0VMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connect

PBT-RB040SG4SE0AMA0Z
Pressure sensors | PBT | PBT-RB040SG4SE0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connect

PBT-RB040SGESECALA0Z
Pressure sensors | PBT | PBT-RB040SGESECALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Copper | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection ty

PBT-RB040SGESESALA0Z
Pressure sensors | PBT | PBT-RB040SGESESALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Stainless steel | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conn

PBT-RB040SGESSCVLC0Z
Pressure sensors | PBT | PBT-RB040SGESSCVLC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Copper | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: L

PBT-RB040SGESSSAMA0Z
Pressure sensors | PBT | PBT-RB040SGESSSAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Stainless steel | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connect

PBT-RB040SGTNSNAMA0Z
Pressure sensors | PBT | PBT-RB040SGTNSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Con

PBT-RB040SGTSSFAMA0Z
Pressure sensors | PBT | PBT-RB040SGTSSFAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type

PBT-RB040SGTSSNALA0Z
Pressure sensors | PBT | PBT-RB040SGTSSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type

PBT-RB040SGTSSNAMA0Z
Pressure sensors | PBT | PBT-RB040SGTSSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type

PBT-RB040SGTSSNVMC0Z
Pressure sensors | PBT | PBT-RB040SGTSSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB040SN1SS0AMA0Z
Pressure sensors | PBT | PBT-RB040SN1SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type:

PBT-RB040SNFSE0ALA0Z
Pressure sensors | PBT | PBT-RB040SNFSE0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼" NPT female | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connec

PBT-RB040SNFSE0AMA0Z
Pressure sensors | PBT | PBT-RB040SNFSE0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼" NPT female | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connec

PBT-RB040SNFSS0VMC0Z
Pressure sensors | PBT | PBT-RB040SNFSS0VMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼" NPT female | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection ty

PBT-RB040SU1SEFAMA0Z
Pressure sensors | PBT | PBT-RB040SU1SEFAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conn

PBT-RB040SU1SEFVMC0Z
Pressure sensors | PBT | PBT-RB040SU1SEFVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connec

PBT-RB040SU1SFFAMA0Z
Pressure sensors | PBT | PBT-RB040SU1SFFAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connec

PBT-RB060SG1MENR2R0Z
Pressure sensors | PBT | PBT-RB060SG1MENR2R0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0.5 V ... 4.5 V, ratiomet

PBT-RB060SG1MSNV2C0Z
Pressure sensors | PBT | PBT-RB060SG1MSNV2C0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Conne

PBT-RB060SG1NSNAMA0Z
Pressure sensors | PBT | PBT-RB060SG1NSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Con

PBT-RB060SG1NSNVMC0Z
Pressure sensors | PBT | PBT-RB060SG1NSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Conne

PBT-RB060SG1SEFALA0Z
Pressure sensors | PBT | PBT-RB060SG1SEFALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t