Сензори за налягане
Pressure Sensors
3216 продукта · стр. 54/134

PBT-RB025SG1SSNVMC0Z
Pressure sensors | PBT | PBT-RB025SG1SSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB025SG2SE0AMA0Z
Pressure sensors | PBT | PBT-RB025SG2SE0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-RB025SG2SE0VMC0V
Pressure sensors | PBT | PBT-RB025SG2SE0VMC0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Conn

PBT-RB025SG2SS0ALA0Z
Pressure sensors | PBT | PBT-RB025SG2SS0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conne

PBT-RB025SG2SS0AMA0Z
Pressure sensors | PBT | PBT-RB025SG2SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conne

PBT-RB025SG2SS0VMC0Z
Pressure sensors | PBT | PBT-RB025SG2SS0VMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connect

PBT-RB025SG4SE0ALA0Z
Pressure sensors | PBT | PBT-RB025SG4SE0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conne

PBT-RB025SG4SFSRMR0Z
Pressure sensors | PBT | PBT-RB025SG4SFSRMR0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: Stainless steel | Communication interface: - | Output signal: 0.5 V ... 4.5 V, ratiometric,

PBT-RB025SG4SHCALA0Z
Pressure sensors | PBT | PBT-RB025SG4SHCALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –40 °C ... +100 °C | Seal: Copper | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection ty

PBT-RB025SGESESVMC0Z
Pressure sensors | PBT | PBT-RB025SGESESVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Stainless steel | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connec

PBT-RB025SGESSSRLR0V
Pressure sensors | PBT | PBT-RB025SGESSSRLR0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Stainless steel | Communication interface: - | Output signal: 0.5 V ... 4.5 V, ratiometric, 3-

PBT-RB025SGTSSNALA0Z
Pressure sensors | PBT | PBT-RB025SGTSSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type

PBT-RB025SGTSSNVLC0Z
Pressure sensors | PBT | PBT-RB025SGTSSNVLC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB025SGTSSNVMC0Z
Pressure sensors | PBT | PBT-RB025SGTSSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB025SN1SE0AMA0V
Pressure sensors | PBT | PBT-RB025SN1SE0AMA0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-RB025SN1SF0ALA0Z
Pressure sensors | PBT | PBT-RB025SN1SF0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-RB025SN1SS0ALA0Z
Pressure sensors | PBT | PBT-RB025SN1SS0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type:

PBT-RB025SN1SS0U2A0Z
Pressure sensors | PBT | PBT-RB025SN1SS0U2A0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type: Fly

PBT-RB040AG1SENAMA0V
Pressure sensors | PBT | PBT-RB040AG1SENAMA0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-RB040AG1SENVMC0G
Pressure sensors | PBT | PBT-RB040AG1SENVMC0G | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection t

PBT-RB040AG1SFFLLM0Z
Pressure sensors | PBT | PBT-RB040AG1SFFLLM0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 1 V ... 6 V, 3-conductor | Connecti

PBT-RB040AG1SSFALA0Z
Pressure sensors | PBT | PBT-RB040AG1SSFALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection ty

PBT-RB040AG1SSNALA0Z
Pressure sensors | PBT | PBT-RB040AG1SSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection ty

PBT-RB040AG2SS0AMA0Z
Pressure sensors | PBT | PBT-RB040AG2SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Con