Сензори за налягане

Pressure Sensors

3216 продукта · стр. 41/134

PBT-CB010SGESS0AMA0Z
6042674

PBT-CB010SGESS0AMA0Z

SICK

Pressure sensors | PBT | PBT-CB010SGESS0AMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conne

PBT-CB010SGTSENAMA0Z
6087648

PBT-CB010SGTSENAMA0Z

SICK

Pressure sensors | PBT | PBT-CB010SGTSENAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connectio

PBT-CB010SGTSENVMC0Z
6061712

PBT-CB010SGTSENVMC0Z

SICK

Pressure sensors | PBT | PBT-CB010SGTSENVMC0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection

PBT-CB010SN1SS0AMA0Z
6043500

PBT-CB010SN1SS0AMA0Z

SICK

Pressure sensors | PBT | PBT-CB010SN1SS0AMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-CB010SN1SS0VMC0Z
6043380

PBT-CB010SN1SS0VMC0Z

SICK

Pressure sensors | PBT | PBT-CB010SN1SS0VMC0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-CB016AG1SSNAMA0Z
6071630

PBT-CB016AG1SSNAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016AG1SSNAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connectio

PBT-CB016AG1SSNR2R0Z
6083479

PBT-CB016AG1SSNR2R0Z

SICK

Pressure sensors | PBT | PBT-CB016AG1SSNR2R0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0.5 V ... 4.5 V, ratiometric, 3-co

PBT-CB016SG1SEFALA0Z
6042051

PBT-CB016SG1SEFALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SEFALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connecti

PBT-CB016SG1SEFVMC0Z
6070118

PBT-CB016SG1SEFVMC0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SEFVMC0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection

PBT-CB016SG1SENALA0Z
6084274

PBT-CB016SG1SENALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SENALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connecti

PBT-CB016SG1SENAMA0Z
6072000

PBT-CB016SG1SENAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SENAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connecti

PBT-CB016SG1SFFWMA0Z
6086715

PBT-CB016SG1SFFWMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SFFWMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 1 V ... 5 V, 3-conductor | Connec

PBT-CB016SG1SSNAMA0Z
6038695

PBT-CB016SG1SSNAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SSNAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-CB016SG1SSNVMC0Z
6038696

PBT-CB016SG1SSNVMC0Z

SICK

Pressure sensors | PBT | PBT-CB016SG1SSNVMC0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection ty

PBT-CB016SG2SS0ALA0Z
6090591

PBT-CB016SG2SS0ALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG2SS0ALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | C

PBT-CB016SG2SS0AMA0Z
6038712

PBT-CB016SG2SS0AMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG2SS0AMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | C

PBT-CB016SG2SS0VMC0Z
6038713

PBT-CB016SG2SS0VMC0Z

SICK

Pressure sensors | PBT | PBT-CB016SG2SS0VMC0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Con

PBT-CB016SG4SESALA0Z
6089204

PBT-CB016SG4SESALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SG4SESALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Stainless steel | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire |

PBT-CB016SGESESALA0Z
6072397

PBT-CB016SGESESALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SGESESALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Stainless steel | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire |

PBT-CB016SGTSEFAMA0Z
6068590

PBT-CB016SGTSEFAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SGTSEFAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connecti

PBT-CB016SGTSSNAMA0Z
6070614

PBT-CB016SGTSSNAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SGTSSNAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-CB016SN1SE0AMA0Z
6078834

PBT-CB016SN1SE0AMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SN1SE0AMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-CB016SU1SFFALA0Z
6088298

PBT-CB016SU1SFFALA0Z

SICK

Pressure sensors | PBT | PBT-CB016SU1SFFALA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-CB016SU1SFFAMA0Z
6075250

PBT-CB016SU1SFFAMA0Z

SICK

Pressure sensors | PBT | PBT-CB016SU1SFFAMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co