Сензори за налягане
Pressure Sensors
3216 продукта · стр. 39/134

PBT-ABX25SG1SFFAMA0Z
Pressure sensors | PBT | PBT-ABX25SG1SFFAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connect

PBT-ABX25SG1SSNAMA0Z
Pressure sensors | PBT | PBT-ABX25SG1SSNAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-ABX25SG1SSNVMC0Z
Pressure sensors | PBT | PBT-ABX25SG1SSNVMC0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection t

PBT-ABX25SGESSSAMA0Z
Pressure sensors | PBT | PBT-ABX25SGESSSAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Stainless steel | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-ABX40AG1SSFALA0Z
Pressure sensors | PBT | PBT-ABX40AG1SSFALA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connectio

PBT-ABX40AN1SS0ALA0Z
Pressure sensors | PBT | PBT-ABX40AN1SS0ALA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-ABX40SG1SSNAMA0Z
Pressure sensors | PBT | PBT-ABX40SG1SSNAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-ABX40SG2SS0AMA0Z
Pressure sensors | PBT | PBT-ABX40SG2SS0AMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | C

PBT-ABX40SGTSENALA0Z
Pressure sensors | PBT | PBT-ABX40SGTSENALA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connecti

PBT-ABX60AG1NSNA2A0Z
Pressure sensors | PBT | PBT-ABX60AG1NSNA2A0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire

PBT-ABX60AGTESNAMA0Z
Pressure sensors | PBT | PBT-ABX60AGTESNAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: 10 mm | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBT-ABX60SG1SSNAMA0Z
Pressure sensors | PBT | PBT-ABX60SG1SSNAMA0Z | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-AMX10SM2SE0AMA0Z
Pressure sensors | PBT | PBT-AMX10SM2SE0AMA0Z | Pressure type: Absolute pressure | Pressure unit: MPa | Measuring range: 0 MPa ... 0.1 MPa | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: M20 x 1.5 (DIN 16288) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wir

PBT-AMX60SG1SSNA2A0Z
Pressure sensors | PBT | PBT-AMX60SG1SSNA2A0Z | Pressure type: Absolute pressure | Pressure unit: MPa | Measuring range: 0 MPa ... 0.6 MPa | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-AP015AN1SS0ALA0Z
Pressure sensors | PBT | PBT-AP015AN1SS0ALA0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 15 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBT-AP015AN1SS0AMA0Z
Pressure sensors | PBT | PBT-AP015AN1SS0AMA0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 15 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBT-AP015AN1SS0VLC0Z
Pressure sensors | PBT | PBT-AP015AN1SS0VLC0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 15 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection typ

PBT-AP015SN1SS0AMA0Z
Pressure sensors | PBT | PBT-AP015SN1SS0AMA0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 15 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-AP025SG1SSFAMA0Z
Pressure sensors | PBT | PBT-AP025SG1SSFAMA0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 25 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBT-AP025SN1SS0ALA0Z
Pressure sensors | PBT | PBT-AP025SN1SS0ALA0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 25 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-AP030AG1NENV2C0Z
Pressure sensors | PBT | PBT-AP030AG1NENV2C0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 30 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire

PBT-AP030AG1NSNV2C0Z
Pressure sensors | PBT | PBT-AP030AG1NSNV2C0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 30 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire |

PBT-AP030AN1SE0ALA0H
Pressure sensors | PBT | PBT-AP030AN1SE0ALA0H | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 30 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connectio

PBT-AP030SN1SS0U2A0Z
Pressure sensors | PBT | PBT-AP030SN1SS0U2A0Z | Pressure type: Absolute pressure | Pressure unit: psi | Measuring range: 0 psi ... 30 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type: