Сензори за налягане

Pressure Sensors

3216 продукта · стр. 130/134

PHT-RBX60S650S0ALS0Z
6039390

PHT-RBX60S650S0ALS0Z

SICK

Pressure sensors | PHT | PHT-RBX60S650S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-conne

PHT-RBX60S650S0AMS0Z
6039334

PHT-RBX60S650S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60S650S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 rou

PHT-RBX60SD30S0AFT0Z
6039411

PHT-RBX60SD30S0AFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD30S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply volta

PHT-RBX60SD30S0ALS0Z
6039355

PHT-RBX60SD30S0ALS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD30S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A),

PHT-RBX60SD30S0AMS0Z
6039299

PHT-RBX60SD30S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD30S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP

PHT-RBX60SD40S0AFT0Z
6039418

PHT-RBX60SD40S0AFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD40S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply volta

PHT-RBX60SD40S0ALS0Z
6039362

PHT-RBX60SD40S0ALS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD40S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A),

PHT-RBX60SD40S0AMS0Z
6039306

PHT-RBX60SD40S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SD40S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP

PHT-RBX60ST10S0AFT0Z
6039404

PHT-RBX60ST10S0AFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST10S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply vo

PHT-RBX60ST10S0ALS0Z
6039348

PHT-RBX60ST10S0ALS0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST10S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803

PHT-RBX60ST10S0AMS0Z
6039292

PHT-RBX60ST10S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST10S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin,

PHT-RBX60ST20S0A5S0Z
6080721

PHT-RBX60ST20S0A5S0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST20S0A5S0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Flying leads, 3 m, IP68 | Supply

PHT-RBX60ST20S0AFT0Z
6081086

PHT-RBX60ST20S0AFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST20S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply volt

PHT-RBX60ST20S0AMS0Z
6076739

PHT-RBX60ST20S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST20S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, I

PHT-RBX60ST20SEAFT0Z
6081087

PHT-RBX60ST20SEAFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60ST20SEAFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply voltage: 11

PHT-RBX60SVF0S0AFT0Z
6039453

PHT-RBX60SVF0S0AFT0Z

SICK

Pressure sensors | PHT | PHT-RBX60SVF0S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Varivent connection type F | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply vo

PHT-RBX60SVF0S0ALS0Z
6039397

PHT-RBX60SVF0S0ALS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SVF0S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Varivent connection type F | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803

PHT-RBX60SVF0S0AMS0Z
6039341

PHT-RBX60SVF0S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RBX60SVF0S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Varivent connection type F | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin,

PHT-RP010ET10SEAMS0Z
6048184

PHT-RP010ET10SEAMS0Z

SICK

Pressure sensors | PHT | PHT-RP010ET10SEAMS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 10 psi | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 |

PHT-RP060ET10SEALS0Z
6041234

PHT-RP060ET10SEALS0Z

SICK

Pressure sensors | PHT | PHT-RP060ET10SEALS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 60 psi | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65

PHT-RP060ET10SEAMS0Z
6050735

PHT-RP060ET10SEAMS0Z

SICK

Pressure sensors | PHT | PHT-RP060ET10SEAMS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 60 psi | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 |

PHT-RP100ST10S0AMS0Z
6063791

PHT-RP100ST10S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RP100ST10S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 100 psi | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin,

PHT-RP200ST10S0AMS0Z
6068342

PHT-RP200ST10S0AMS0Z

SICK

Pressure sensors | PHT | PHT-RP200ST10S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 200 psi | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin,

PHT-RP300ET10SEALS0Z
6067380

PHT-RP300ET10SEALS0Z

SICK

Pressure sensors | PHT | PHT-RP300ET10SEALS0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 300 psi | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP6