Сензори за налягане
Pressure Sensors
3216 продукта · стр. 122/134

PHT-RB025E520S0AFT0Z
Pressure sensors | PHT | PHT-RB025E520S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field ho

PHT-RB025E520S0ALS0Z
Pressure sensors | PHT | PHT-RB025E520S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connec

PHT-RB025E520S0AMS0Z
Pressure sensors | PHT | PHT-RB025E520S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 roun

PHT-RB025S520S0ALS0Z
Pressure sensors | PHT | PHT-RB025S520S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connect

PHT-RB025S520S0AMS0Z
Pressure sensors | PHT | PHT-RB025S520S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

PHT-RB025S540S0AFT0Z
Pressure sensors | PHT | PHT-RB025S540S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 40 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field hou

PHT-RB025S540S0ALS0Z
Pressure sensors | PHT | PHT-RB025S540S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 40 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connect

PHT-RB025S540S0AMS0Z
Pressure sensors | PHT | PHT-RB025S540S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 40 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

PHT-RB025S550S0AFT0Z
Pressure sensors | PHT | PHT-RB025S550S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 50 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field hou

PHT-RB025S550S0ALS0Z
Pressure sensors | PHT | PHT-RB025S550S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 50 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connect

PHT-RB025S550S0AMS0Z
Pressure sensors | PHT | PHT-RB025S550S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 50 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

PHT-RB025S640S0AFT0Z
Pressure sensors | PHT | PHT-RB025S640S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 40 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field ho

PHT-RB025S640S0ALS0Z
Pressure sensors | PHT | PHT-RB025S640S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 40 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connec

PHT-RB025S640S0AMS0Z
Pressure sensors | PHT | PHT-RB025S640S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 40 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 roun

PHT-RB025S650S0AFT0Z
Pressure sensors | PHT | PHT-RB025S650S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field ho

PHT-RB025S650S0ALS0Z
Pressure sensors | PHT | PHT-RB025S650S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connec

PHT-RB025S650S0AMS0Z
Pressure sensors | PHT | PHT-RB025S650S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 roun

PHT-RB025SD30S0AFT0Z
Pressure sensors | PHT | PHT-RB025SD30S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply voltag

PHT-RB025SD30S0ALS0Z
Pressure sensors | PHT | PHT-RB025SD30S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A),

PHT-RB025SD30S0AMS0Z
Pressure sensors | PHT | PHT-RB025SD30S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP6

PHT-RB025SD40S0AFT0Z
Pressure sensors | PHT | PHT-RB025SD40S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply voltag

PHT-RB025SD40S0ALS0Z
Pressure sensors | PHT | PHT-RB025SD40S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A),

PHT-RB025SD40S0AMS0Z
Pressure sensors | PHT | PHT-RB025SD40S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP6

PHT-RB025ST10S0AFT0Z
Pressure sensors | PHT | PHT-RB025ST10S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply vol