Превключватели за безопасност
Safety Switches
313 продукта · стр. 7/14

RE13-SA84
Safety switches | RE1 | RE13-SA84 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable with M8 male connector, 4-pin | Length of cable: 0.2 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE13-SAC
Safety switches | RE1 | RE13-SAC | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Plug connector, M8, 4-pin | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE15-SA03
Safety switches | RE1 | RE15-SA03 | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 1 | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE15-SAC
Safety switches | RE1 | RE15-SAC | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 0 | Connection type Detail: Plug connector, M8, 4-pin | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE21-SA03
Safety switches | RE2 | RE21-SA03 | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 0 | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE21-SA05
Safety switches | RE2 | RE21-SA05 | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 0 | Connection type Detail: Cable | Length of cable: 5 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE21-SA84
Safety switches | RE2 | RE21-SA84 | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 0 | Connection type Detail: Cable with M8 male connector, 4-pin | Length of cable: 0.2 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE21-SAC
Safety switches | RE2 | RE21-SAC | Systemteil: Sensor with actuator | N/O contacts: 1 | N/C contacts: 1 | Signaling contacts: 0 | Connection type Detail: Plug connector, M8, 4-pin | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE23-SA03
Safety switches | RE2 | RE23-SA03 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE23-SA05
Safety switches | RE2 | RE23-SA05 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable | Length of cable: 5 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE23-SA10
Safety switches | RE2 | RE23-SA10 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE23-SA64
Safety switches | RE2 | RE23-SA64 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable with plug, M12, 4-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: no

RE23-SA84
Safety switches | RE2 | RE23-SA84 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Cable with M8 male connector, 4-pin | Length of cable: 0.2 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: no

RE23-SAC
Safety switches | RE2 | RE23-SAC | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 0 | Connection type Detail: Plug connector, M8, 4-pin | Safe series connection: With Flexi Loop (with diagnostics) | Status display: no

RE27-SA05L
Safety switches | RE2 | RE27-SA05L | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable | Length of cable: 5 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: yes

RE27-SA10L
Safety switches | RE2 | RE27-SA10L | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: yes

RE27-SA20L
Safety switches | RE2 | RE27-SA20L | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable | Length of cable: 20 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: yes

RE27-SA68L
Safety switches | RE2 | RE27-SA68L | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: None, only individual wiring (with diagnostics) | Status display: yes

RE27-SA68LS04
Safety switches | RE2 | RE27-SA68LS04 | Systemteil: Sensor with actuator | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes

RE27-SB68LS04
Safety switches | RE2 | RE27-SB68LS04 | Systemteil: sensor | N/O contacts: 2 | N/C contacts: 0 | Signaling contacts: 1 | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes

SE1-SS1A20
Safety switches | safeIDS | SE1-SS1A20 | IO-Link Safety: IO-Link Safety V1.1.4 | Active sensor surface: Front | Assured switch on distance Sao: 7 mm | Connection type Detail: Plug, M12, 4-pin, A-coded | Note: The actuator has to be ordered separately. See "Accessories" for further details., Because no parameter configuration is required, there is no “dedicated tool” for this product.

SE1-ST1A20
Safety switches | safeIDS | SE1-ST1A20 | IO-Link Safety: IO-Link Safety V1.1.4 | Active sensor surface: Top | Assured switch on distance Sao: 10 mm | Connection type Detail: Plug, M12, 4-pin, A-coded | Note: The actuator has to be ordered separately. See "Accessories" for further details., Because no parameter configuration is required, there is no “dedicated tool” for this product.

STR1-SACM0AC8
Safety switches | STR1 | STR1-SACM0AC8 | Actuator design: Compact | Coding: Universally coded | Assured switch on distance Sao: 10 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With T-connector (without diagnostics), with Flexi Loop (with diagnostics) | Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs)

STR1-SACM0PR5
Safety switches | STR1 | STR1-SACM0PR5 | Actuator design: Compact | Coding: Universally coded | Assured switch on distance Sao: 10 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Auxiliary contact (AUX): 1 (switching behavior equivalent to actuator in the protected switch-on state)