Превключватели за безопасност
Safety Switches
313 продукта · стр. 13/14

TR4-SBU10PB
Safety switches | TR4 Direct | TR4-SBU10PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 25 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDM01CB
Safety switches | TR4 Direct | TR4-SDM01CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDM02CB
Safety switches | TR4 Direct | TR4-SDM02CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDM03PB
Safety switches | TR4 Direct | TR4-SDM03PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDM10PB
Safety switches | TR4 Direct | TR4-SDM10PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDU01CB
Safety switches | TR4 Direct | TR4-SDU01CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDU02CB
Safety switches | TR4 Direct | TR4-SDU02CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDU03PB
Safety switches | TR4 Direct | TR4-SDU03PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SDU10PB
Safety switches | TR4 Direct | TR4-SDU10PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

TR4-SEM01CB
Safety switches | TR4 Direct | TR4-SEM01CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEM02CB
Safety switches | TR4 Direct | TR4-SEM02CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEM03PB
Safety switches | TR4 Direct | TR4-SEM03PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEM10PB
Safety switches | TR4 Direct | TR4-SEM10PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEU01CB
Safety switches | TR4 Direct | TR4-SEU01CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEU02CB
Safety switches | TR4 Direct | TR4-SEU02CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEU03PB
Safety switches | TR4 Direct | TR4-SEU03PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SEU10PB
Safety switches | TR4 Direct | TR4-SEU10PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFM01CB
Safety switches | TR4 Direct | TR4-SFM01CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFM02CB
Safety switches | TR4 Direct | TR4-SFM02CB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFM03PB
Safety switches | TR4 Direct | TR4-SFM03PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFM10PB
Safety switches | TR4 Direct | TR4-SFM10PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFU01CB
Safety switches | TR4 Direct | TR4-SFU01CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFU02CB
Safety switches | TR4 Direct | TR4-SFU02CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 5-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics) | Status display: yes | Boundary area indication: yes

TR4-SFU03PB
Safety switches | TR4 Direct | TR4-SFU03PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: yes