Светлинни бариери

Safety Light Beam Sensors

232 продукта · стр. 8/10

M4P-SA02500A00, M4P-EA02500D00
p683732

M4P-SA02500A00, M4P-EA02500D00

SICK

Safety light-beam sensors | deTem | M4P-SA02500A00, M4P-EA02500D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 ma

M4P-SA02500B00
1128431

M4P-SA02500B00

SICK

Safety light-beam sensors | deTem | M4P-SA02500B00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Sender | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 male connector,

M4P-SA02500B00, M4P-EA02500C00
p683736

M4P-SA02500B00, M4P-EA02500C00

SICK

Safety light-beam sensors | deTem | M4P-SA02500B00, M4P-EA02500C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 ma

M4P-SA02500B00, M4P-EA02500D00
p683739

M4P-SA02500B00, M4P-EA02500D00

SICK

Safety light-beam sensors | deTem | M4P-SA02500B00, M4P-EA02500D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 ma

M4P-SA03400A00
1128428

M4P-SA03400A00

SICK

Safety light-beam sensors | deTem | M4P-SA03400A00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Sender | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 male connector,

M4P-SA03400A00, M4P-EA03400C00
p683730

M4P-SA03400A00, M4P-EA03400C00

SICK

Safety light-beam sensors | deTem | M4P-SA03400A00, M4P-EA03400C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 ma

M4P-SA03400A00, M4P-EA03400D00
p683733

M4P-SA03400A00, M4P-EA03400D00

SICK

Safety light-beam sensors | deTem | M4P-SA03400A00, M4P-EA03400D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 ma

M4P-SA03400B00
1128432

M4P-SA03400B00

SICK

Safety light-beam sensors | deTem | M4P-SA03400B00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Sender | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 male connector,

M4P-SA03400B00, M4P-EA03400C00
p683737

M4P-SA03400B00, M4P-EA03400C00

SICK

Safety light-beam sensors | deTem | M4P-SA03400B00, M4P-EA03400C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 ma

M4P-SA03400B00, M4P-EA03400D00
p683740

M4P-SA03400B00, M4P-EA03400D00

SICK

Safety light-beam sensors | deTem | M4P-SA03400B00, M4P-EA03400D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 3 | Beam separation: 400 mm | Connection type: Depending on system plug (M12 ma

M4P-SA04300A00
1128429

M4P-SA04300A00

SICK

Safety light-beam sensors | deTem | M4P-SA04300A00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Sender | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male connector,

M4P-SA04300A00, M4P-EA04300C00
p683731

M4P-SA04300A00, M4P-EA04300C00

SICK

Safety light-beam sensors | deTem | M4P-SA04300A00, M4P-EA04300C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 ma

M4P-SA04300A00, M4P-EA04300D00
p683734

M4P-SA04300A00, M4P-EA04300D00

SICK

Safety light-beam sensors | deTem | M4P-SA04300A00, M4P-EA04300D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 ma

M4P-SA04300B00
1128433

M4P-SA04300B00

SICK

Safety light-beam sensors | deTem | M4P-SA04300B00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Sender | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male connector,

M4P-SA04300B00, M4P-EA04300C00
p683738

M4P-SA04300B00, M4P-EA04300C00

SICK

Safety light-beam sensors | deTem | M4P-SA04300B00, M4P-EA04300C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 ma

M4P-SA04300B00, M4P-EA04300D00
p683741

M4P-SA04300B00, M4P-EA04300D00

SICK

Safety light-beam sensors | deTem | M4P-SA04300B00, M4P-EA04300D00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 ma

M4P-ZA02500C00
1102633

M4P-ZA02500C00

SICK

Safety light-beam sensors | deTem | M4P-ZA02500C00 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Active unit | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 3.2 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 male co

M4P-ZA02500C00, PSN01-2501
p655513

M4P-ZA02500C00, PSN01-2501

SICK

Safety light-beam sensors | deTem | M4P-ZA02500C00, PSN01-2501 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 3.2 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 ma

M4P-ZA02500D00
1102635

M4P-ZA02500D00

SICK

Safety light-beam sensors | deTem | M4P-ZA02500D00 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Active unit | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 3.2 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 male co

M4P-ZA02500D00, PSN01-2501
p655518

M4P-ZA02500D00, PSN01-2501

SICK

Safety light-beam sensors | deTem | M4P-ZA02500D00, PSN01-2501 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 3.2 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Depending on system plug (M12 ma

M4P-ZA04300C00
1102634

M4P-ZA04300C00

SICK

Safety light-beam sensors | deTem | M4P-ZA04300C00 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Active unit | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 7 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male conn

M4P-ZA04300C00, PSN02-2301
p655514

M4P-ZA04300C00, PSN02-2301

SICK

Safety light-beam sensors | deTem | M4P-ZA04300C00, PSN02-2301 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 3.2 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 ma

M4P-ZA04300C00, PSN02-3301
p655517

M4P-ZA04300C00, PSN02-3301

SICK

Safety light-beam sensors | deTem | M4P-ZA04300C00, PSN02-3301 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 7 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male

M4P-ZA04300D00
1102636

M4P-ZA04300D00

SICK

Safety light-beam sensors | deTem | M4P-ZA04300D00 | Product version: deTem4 A/P | Functional principle: Active/passive | System part: Active unit | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 7 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male conn