Енкодери за безопасност

Safety Encoders

1037 продукта · стр. 42/44

DFS60S-S1OD01024
1111093

DFS60S-S1OD01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1OD01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, axial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S1OJ01024
1102112

DFS60S-S1OJ01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1OJ01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 0.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S1OK01024
1069523

DFS60S-S1OK01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1OK01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S1OL01024
1122322

DFS60S-S1OL01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1OL01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 3 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S1OM01024
1089265

DFS60S-S1OM01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1OM01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S1ON01024
1140516

DFS60S-S1ON01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S1ON01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 10 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OA01024
1069518

DFS60S-S4OA01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OA01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OB01024
p382246

DFS60S-S4OB01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OB01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, axial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OC01024
1069519

DFS60S-S4OC01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OC01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OD01024
1093665

DFS60S-S4OD01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OD01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, axial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OJ01024
p382248

DFS60S-S4OJ01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OJ01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 0.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OK01024
1069520

DFS60S-S4OK01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OK01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OL01024
1087907

DFS60S-S4OL01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OL01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 3 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4OM01024
1089266

DFS60S-S4OM01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4OM01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-S4ON01024
1127590

DFS60S-S4ON01024

SICK

Safety encoders | DFS60S Pro | DFS60S-S4ON01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 10 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SDOA01024
1067910

DFS60S-SDOA01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SDOA01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SDOC01024
1069524

DFS60S-SDOC01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SDOC01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SDOK01024
1069525

DFS60S-SDOK01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SDOK01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SEOA01024
1069521

DFS60S-SEOA01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SEOA01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SEOC01024
1067912

DFS60S-SEOC01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SEOC01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SEOD01024
1072182

DFS60S-SEOD01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SEOD01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M12, 8-pin, axial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SEOK01024
1067913

DFS60S-SEOK01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SEOK01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SEOL01024
1092884

DFS60S-SEOL01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SEOL01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Cable, 8-wire, universal, 3 m | Sine/cosine periods per revolution: 1,024 | Anti-dither: no

DFS60S-SFOA01024
1077618

DFS60S-SFOA01024

SICK

Safety encoders | DFS60S Pro | DFS60S-SFOA01024 | Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Performance level: PL d (EN ISO 13849) | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial | Sine/cosine periods per revolution: 1,024 | Anti-dither: no