Енкодери за безопасност
Safety Encoders
1037 продукта · стр. 15/44

AFM60S-SJSK262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSK262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 1.5 m

AFM60S-SJSL262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSL262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 3 m

AFM60S-SJSN262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSN262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 10 m

AFM60S-SJSR262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSR262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, axial, 1.5 m

AFM60S-SJSS262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSS262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, axial, 3 m

AFM60S-SJST262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJST262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, axial, 5 m

AFM60S-SJSU262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSU262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, axial, 10 m

AFM60S-TAKA262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKA262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial

AFM60S-TAKC262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKC262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Male connector, M12, 12-pin, radial

AFM60S-TAKJ262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKJ262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 0.5 m

AFM60S-TAKK262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKK262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 1.5 m

AFM60S-TAKL262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKL262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 3 m

AFM60S-TAKM262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKM262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 5 m

AFM60S-TAKN262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TAKN262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 10 m

AFM60S-TASA262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASA262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Male connector, M23, 12-pin, radial

AFM60S-TASC262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASC262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Male connector, M12, 12-pin, radial

AFM60S-TASJ262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASJ262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 0.5 m

AFM60S-TASK262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASK262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 1.5 m

AFM60S-TASL262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASL262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 3 m

AFM60S-TASM262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASM262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 5 m

AFM60S-TASN262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TASN262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 6 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 10 m

AFM60S-TBKA262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TBKA262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 8 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Male connector, M23, 12-pin, radial

AFM60S-TBKC262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TBKC262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 8 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Male connector, M12, 12-pin, radial

AFM60S-TBKJ262144
Safety encoders | AFS/AFM60S Pro | AFM60S-TBKJ262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Through hollow shaft 8 mm (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, non programmable | Connection type: Cable, 12-wire, radial, 0.5 m