PBT-RB250AG4SE0ALA0V
6074847

PBT-RB250AG4SE0ALA0V

SICK

Pressure sensors | PBT | PBT-RB250AG4SE0ALA0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conn

PBT-RB250AGTSSNALA0Z
6048761

PBT-RB250AGTSSNALA0Z

SICK

Pressure sensors | PBT | PBT-RB250AGTSSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBT-RB250SG1MENVMC0Z
6066138

PBT-RB250SG1MENVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1MENVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | C

PBT-RB250SG1MSNALA0Z
6067892

PBT-RB250SG1MSNALA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1MSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-RB250SG1MSNAMA0Z
6053592

PBT-RB250SG1MSNAMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1MSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-RB250SG1MSNVMC0Z
6051423

PBT-RB250SG1MSNVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1MSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.6 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Conn

PBT-RB250SG1NENVMC0Z
6066137

PBT-RB250SG1NENVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1NENVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | C

PBT-RB250SG1NFFAMA0Z
6077763

PBT-RB250SG1NFFAMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1NFFAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: –20 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire |

PBT-RB250SG1NSNAMA0Z
6048567

PBT-RB250SG1NSNAMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1NSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

PBT-RB250SG1SEFALA0Z
6048198

PBT-RB250SG1SEFALA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SEFALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-RB250SG1SEFVMC0Z
6050422

PBT-RB250SG1SEFVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SEFVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection ty

PBT-RB250SG1SENAMA0Z
6039572

PBT-RB250SG1SENAMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SENAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

PBT-RB250SG1SENUMA0V
6081673

PBT-RB250SG1SENUMA0V

SICK

Pressure sensors | PBT | PBT-RB250SG1SENUMA0V | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection typ

PBT-RB250SG1SENUMA0Z
6051461

PBT-RB250SG1SENUMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SENUMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection typ

PBT-RB250SG1SENWLA0Z
6078795

PBT-RB250SG1SENWLA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SENWLA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 1 V ... 5 V, 3-conductor | Connectio

PBT-RB250SG1SSFVLC0Z
6066907

PBT-RB250SG1SSFVLC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSFVLC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB250SG1SSFVMC0Z
6055045

PBT-RB250SG1SSFVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSFVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB250SG1SSNALA0Z
6041438

PBT-RB250SG1SSNALA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-RB250SG1SSNAMA0Z
6038652

PBT-RB250SG1SSNAMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

PBT-RB250SG1SSNULA0Z
6050348

PBT-RB250SG1SSNULA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNULA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type:

PBT-RB250SG1SSNUMA0Z
6041570

PBT-RB250SG1SSNUMA0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNUMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type:

PBT-RB250SG1SSNVLC0H
6070317

PBT-RB250SG1SSNVLC0H

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNVLC0H | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB250SG1SSNVLC0Z
6047659

PBT-RB250SG1SSNVLC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNVLC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type:

PBT-RB250SG1SSNVMC0Z
6038654

PBT-RB250SG1SSNVMC0Z

SICK

Pressure sensors | PBT | PBT-RB250SG1SSNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: