Сензори за налягане

Pressure Sensors

3216 продукта · стр. 11/134

PBS2-CB025SG1SSDQ5A0Z
6074229

PBS2-CB025SG1SSDQ5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SG1SSDQ5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output s

PBS2-CB025SG2SS0LMA0Z
6074184

PBS2-CB025SG2SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SG2SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link

PBS2-CB025SG2SS0NMA0Z
6073482

PBS2-CB025SG2SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SG2SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link

PBS2-CB025SG2SS0Q5A0Z
6074236

PBS2-CB025SG2SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SG2SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link

PBS2-CB025SN1SS0LMA0Z
6074191

PBS2-CB025SN1SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SN1SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sig

PBS2-CB025SN1SS0NMA0Z
6074216

PBS2-CB025SN1SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SN1SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sig

PBS2-CB025SN1SS0Q5A0Z
6074244

PBS2-CB025SN1SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB025SN1SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 24 bar, –14.5 psi ... 348 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sig

PBS2-CB1X0SG1SSDLMA0Z
6072948

PBS2-CB1X0SG1SSDLMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SG1SSDLMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output sign

PBS2-CB1X0SG1SSDNMA0Z
6074196

PBS2-CB1X0SG1SSDNMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SG1SSDNMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output sign

PBS2-CB1X0SG2SS0LMA0Z
6074179

PBS2-CB1X0SG2SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SG2SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | O

PBS2-CB1X0SG2SS0NMA0Z
6074203

PBS2-CB1X0SG2SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SG2SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | O

PBS2-CB1X0SG2SS0Q5A0Z
6074230

PBS2-CB1X0SG2SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SG2SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | O

PBS2-CB1X0SN1SS0LMA0Z
6074185

PBS2-CB1X0SN1SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SN1SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output signal

PBS2-CB1X0SN1SS0NMA0Z
6074209

PBS2-CB1X0SN1SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SN1SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output signal

PBS2-CB1X0SN1SS0Q5A0Z
6074237

PBS2-CB1X0SN1SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X0SN1SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0 bar, –14.5 psi ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output signal

PBS2-CB1X6SG1SSDLMA0Z
6072950

PBS2-CB1X6SG1SSDLMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG1SSDLMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output si

PBS2-CB1X6SG1SSDNMA0Z
6074197

PBS2-CB1X6SG1SSDNMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG1SSDNMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output si

PBS2-CB1X6SG1SSDQ5A0Z
6074223

PBS2-CB1X6SG1SSDQ5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG1SSDQ5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link | Output si

PBS2-CB1X6SG2SS0LMA0Z
6074180

PBS2-CB1X6SG2SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG2SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link |

PBS2-CB1X6SG2SS0NMA0Z
6074204

PBS2-CB1X6SG2SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG2SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link |

PBS2-CB1X6SG2SS0Q5A0Z
6074231

PBS2-CB1X6SG2SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SG2SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link |

PBS2-CB1X6SN1SS0LMA0Z
6074186

PBS2-CB1X6SN1SS0LMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SN1SS0LMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sign

PBS2-CB1X6SN1SS0NMA0Z
6074210

PBS2-CB1X6SN1SS0NMA0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SN1SS0NMA0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sign

PBS2-CB1X6SN1SS0Q5A0Z
6074238

PBS2-CB1X6SN1SS0Q5A0Z

SICK

Pressure sensors | PBS plus | PBS2-CB1X6SN1SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 0.6 bar, –14.5 psi ... 9 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link | Output sign