PFT-SCA160SGDSSAAMSSZ
Pressure sensors | PFT | PFT-SCA160SGDSSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –60 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCA250AG2SEAAMSSZ
Pressure sensors | PFT | PFT-SCA250AG2SEAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Press

PFT-SCA250SG1SSAALSSZ
Pressure sensors | PFT | PFT-SCA250SG1SSAALSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressur

PFT-SCA250SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCA250SG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressur

PFT-SCA250SG1SSAVMSSZ
Pressure sensors | PFT | PFT-SCA250SG1SSAVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-SCA250SG2SSAAMSSZ
Pressure sensors | PFT | PFT-SCA250SG2SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressu

PFT-SCA250SG2SSAVMSSZ
Pressure sensors | PFT | PFT-SCA250SG2SSAVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-SCA250SN1SSAVLSSZ
Pressure sensors | PFT | PFT-SCA250SN1SSAVLSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –250 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: ¼'' NPT | Pressure port: Sta

PFT-SCA400AG1SEAAMSSZ
Pressure sensors | PFT | PFT-SCA400AG1SEAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –400 mbar ... 0 mbar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –40 °C ... +125 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCA400AG2SSAAMSSZ
Pressure sensors | PFT | PFT-SCA400AG2SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –400 mbar ... 0 mbar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCA400AN1SSAAMSSZ
Pressure sensors | PFT | PFT-SCA400AN1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –400 mbar ... 0 mbar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCA600AG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCA600AG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –600 mbar ... 0 mbar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCA600SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCA600SG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –600 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressur

PFT-SCA600SG1SSAVMSSZ
Pressure sensors | PFT | PFT-SCA600SG1SSAVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –600 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-SCA600SG2SSAAMSSZ
Pressure sensors | PFT | PFT-SCA600SG2SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –600 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressu

PFT-SCA600SG2SSAVMSSZ
Pressure sensors | PFT | PFT-SCA600SG2SSAVMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –600 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-SCB010AG1SSAALSSZ
Pressure sensors | PFT | PFT-SCB010AG1SSAALSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB010AG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCB010AG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB010AGDSSAAMSSZ
Pressure sensors | PFT | PFT-SCB010AGDSSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB010SG1SEAAMSSZ
Pressure sensors | PFT | PFT-SCB010SG1SEAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure por

PFT-SCB010SG1SSAALSSZ
Pressure sensors | PFT | PFT-SCB010SG1SSAALSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB010SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCB010SG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure por

PFT-SCB010SG1SSAVMSSZ
Pressure sensors | PFT | PFT-SCB010SG1SSAVMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PFT-SCB010SG2SSAAMSSZ
Pressure sensors | PFT | PFT-SCB010SG2SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressure po