Серия ReLy

10 варианта от SICK. Изберете модела, който отговаря на приложението ви, или попитайте нас.

RLY3-EMSS100
1085345

RLY3-EMSS100

SICK

ReLy | RLY3-EMSS100 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-EMSS300
1099973

RLY3-EMSS300

SICK

ReLy | RLY3-EMSS300 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-HAND100
1085346

RLY3-HAND100

SICK

ReLy | RLY3-HAND100 | Applications: Evaluation unit | Compatible sensor types: Two-hand controls Type III C, in accordance with EN ISO 13851 | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 1 application diagnostic output (not safe) | Housing width: 18 mm

RLY3-LOOP100
1100696

RLY3-LOOP100

SICK

ReLy | RLY3-LOOP100 | Applications: Evaluation unit | Compatible sensor types: Flexi Loop safe series connection | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-MULT100
1100692

RLY3-MULT100

SICK

ReLy | RLY3-MULT100 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs, Safety sensors with test input, safety sensors with potential-free outputs, Safety pressure mats | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 2 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-OSSD100
1085343

RLY3-OSSD100

SICK

Safety controllers | ReLy | RLY3-OSSD100 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Via path | Outputs: 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe) | Housing width: 18 mm

RLY3-OSSD200
1085344

RLY3-OSSD200

SICK

ReLy | RLY3-OSSD200 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-OSSD300
1099969

RLY3-OSSD300

SICK

ReLy | RLY3-OSSD300 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-OSSD400
1099971

RLY3-OSSD400

SICK

Safety controllers | ReLy | RLY3-OSSD400 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Via path | Outputs: 4 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe), 1 signaling current path (not safe) | Housing width: 28 mm

RLY3-TIME100
1100688

RLY3-TIME100

SICK

ReLy | RLY3-TIME100 | Applications: Evaluation unit for stop category 1 applications | Compatible sensor types: Safety sensors with OSSDs, safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outpu