RLY3-EMSS100
ReLy | RLY3-EMSS100 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-EMSS300
ReLy | RLY3-EMSS300 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-HAND100
ReLy | RLY3-HAND100 | Applications: Evaluation unit | Compatible sensor types: Two-hand controls Type III C, in accordance with EN ISO 13851 | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 1 application diagnostic output (not safe) | Housing width: 18 mm

RLY3-LOOP100
ReLy | RLY3-LOOP100 | Applications: Evaluation unit | Compatible sensor types: Flexi Loop safe series connection | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-MULT100
ReLy | RLY3-MULT100 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs, Safety sensors with test input, safety sensors with potential-free outputs, Safety pressure mats | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 2 test pulse outputs (not safe) | Housing width: 18 mm

RLY3-OSSD100
Safety controllers | ReLy | RLY3-OSSD100 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Via path | Outputs: 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe) | Housing width: 18 mm

RLY3-OSSD200
ReLy | RLY3-OSSD200 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-OSSD300
ReLy | RLY3-OSSD300 | Applications: Evaluation unit | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) | Housing width: 18 mm

RLY3-OSSD400
Safety controllers | ReLy | RLY3-OSSD400 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Via path | Outputs: 4 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe), 1 signaling current path (not safe) | Housing width: 28 mm

RLY3-TIME100
ReLy | RLY3-TIME100 | Applications: Evaluation unit for stop category 1 applications | Compatible sensor types: Safety sensors with OSSDs, safety sensors with potential-free outputs | Connection type: Front connector with spring terminals | Restart interlock: yes | External device monitoring (EDM): Integrated | Outputs: 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outpu