Светлинни гридове
Automation Light Grids
3060 продукта · стр. 14/128

MLG02A-0745R53201
Automation light grids | MLG-2 | MLG02A-0745R53201 | Device version: Pro - Extended functionality | Inputs/outputs: 4 x Q (IO-Link) | Option: Protective housing IP69K | Beam separation: 2.5 mm | Operating range: 1.5 m | Detection height: 745 mm | Length of cable: 0.39 m, 0.39 m | Response time: 24.3 ms | Software feature (default setting - see technical data/features): 01

MLG02A-0895B13201
Automation light grids | MLG-2 | MLG02A-0895B13201 | Device version: Pro - Extended functionality | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 29 ms | Software feature (default setting - see technical data/features): 01

MLG02A-0895I13201
Automation light grids | MLG-2 | MLG02A-0895I13201 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 29 ms | Software feature (default setting - see technical data/features): 01

MLG02A-0895I13250
Automation light grids | MLG-2 | MLG02A-0895I13250 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 29 ms | Software feature (default setting - see technical data/features): 50

MLG02A-0895R13201
Automation light grids | MLG-2 | MLG02A-0895R13201 | Device version: Pro - Extended functionality | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 29 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1045B13201
Automation light grids | MLG-2 | MLG02A-1045B13201 | Device version: Pro - Extended functionality | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,045 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 33.6 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1045I13201
Automation light grids | MLG-2 | MLG02A-1045I13201 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,045 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 33.6 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1045I13250
Automation light grids | MLG-2 | MLG02A-1045I13250 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,045 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 33.6 ms | Software feature (default setting - see technical data/features): 50

MLG02A-1045R13201
Automation light grids | MLG-2 | MLG02A-1045R13201 | Device version: Pro - Extended functionality | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,045 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 33.6 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1195B13201
Automation light grids | MLG-2 | MLG02A-1195B13201 | Device version: Pro - Extended functionality | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,195 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 38.2 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1195I13201
Automation light grids | MLG-2 | MLG02A-1195I13201 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,195 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 38.2 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1195I13250
Automation light grids | MLG-2 | MLG02A-1195I13250 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,195 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 38.2 ms | Software feature (default setting - see technical data/features): 50

MLG02A-1195R13201
Automation light grids | MLG-2 | MLG02A-1195R13201 | Device version: Pro - Extended functionality | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,195 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 38.2 ms | Software feature (default setting - see technical data/features): 01

MLG02A-1195R13203
Automation light grids | MLG-2 | MLG02A-1195R13203 | Device version: Pro - Extended functionality | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 1,195 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 38.2 ms | Software feature (default setting - see technical data/features): 03

MLG02N-0145C13201
Automation light grids | MLG-2 | MLG02N-0145C13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145E13201
Automation light grids | MLG-2 | MLG02N-0145E13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145E53201
Automation light grids | MLG-2 | MLG02N-0145E53201 | Device version: ProNet – extended functionality including fieldbus | Option: Protective housing IP69K | Beam separation: 2.5 mm | Operating range: 1.5 m | Detection height: 145 mm | Length of cable: 1.4 m, 1.4 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145H13201
Automation light grids | MLG-2 | MLG02N-0145H13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145H53201
Automation light grids | MLG-2 | MLG02N-0145H53201 | Device version: ProNet – extended functionality including fieldbus | Option: Protective housing IP69K | Beam separation: 2.5 mm | Operating range: 1.5 m | Detection height: 145 mm | Length of cable: 1.4 m, 1.4 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145N13201
Automation light grids | MLG-2 | MLG02N-0145N13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145N13301
Automation light grids | MLG-2 | MLG02N-0145N13301 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 3 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145N53201
Automation light grids | MLG-2 | MLG02N-0145N53201 | Device version: ProNet – extended functionality including fieldbus | Option: Protective housing IP69K | Beam separation: 2.5 mm | Operating range: 1.5 m | Detection height: 145 mm | Length of cable: 1.4 m, 1.4 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0145P13201
Automation light grids | MLG-2 | MLG02N-0145P13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 145 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG02N-0295C13201
Automation light grids | MLG-2 | MLG02N-0295C13201 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 2.5 mm | Operating range: 2 m | Detection height: 295 mm | Length of cable: 0.22 m, 0.21 m | Response time: 10.5 ms | Software feature (default setting - see technical data/features): 01