Търсене в каталога
41538 резултата за "SICK" · стр. 819/2077

BEF-GH-MINI02
Mounting systems | Brackets | BEF-GH-MINI02 | Description: Ball clamp bracket | Material: Plastic | Details: Plastic | Items supplied: Mounting hardware included | Suitable for: W2S-2, W4-3

IME18-20NNOZC0S
Inductive proximity sensors | IME | IME18-20NNOZC0S | Housing: Standard design | Sensing range Sn: 20 mm | Installation type: Non-flush | Electrical wiring: DC 3-wire | Switching output: NPN | Output function: NC | Connection type: Male connector M12, 4-pin | Special features: Triple sensing range

DFS60E-S4CB02000
Incremental encoders | DFS60 | DFS60E-S4CB02000 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 10 V ... 32 V, TTL, RS-422 | Connection type: Male connector, M23, 12-pin, axial | Pulses per revolution: 2,000

HTB18-B4B2BED04
Photoelectric sensors | H18 Sure Sense | HTB18-B4B2BED04 | Device version: Standard | Communication interface: - | Mounting system type: M18, head/side (24.1 … 25.4 mm) | Sensor/ detection principle: Photoelectric proximity sensor, Background suppression | Sensing range: 300 mm | Light source, light type: PinPoint LED, visible red light | Voltage type: DC | Switching output Q1: PNP, Light switching | Switching output Q2: NPN, Light switching | Potentiometer, right: Light/dark switching | Potenti

DFS60B-BEEM04096
Incremental encoders | DFS60 | DFS60B-BEEM04096 | Mechanical design: Blind hollow shaft 12 mm (Front clamp) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 5 m | Pulses per revolution: 4,096

IM12-04NAS-ZU0
Inductive proximity sensors | IMO | IM12-04NAS-ZU0 | Housing: Standard design | Sensing range Sn: 4 mm | Installation type: Non-flush | Electrical wiring: AC 2-wire | Output function: NO | Connection type: Cable, 2-wire, 2 m

Fixing screw
Reflectors and optics | Lenses | Fixing screw | Description: Screw for the lenses, for use in combination with lens barrel

DBS60E-B3EQD1024
Incremental encoders | DBS60 | DBS60E-B3EQD1024 | Mechanical design: Blind hollow shaft 3/8″ (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Cable, 8-wire, with male connector, M23, 12-pin, universal, 0.5 m | Pulses per revolution: 1,024 | Flange type / stator coupling: 1-sided stator coupling, slot, screw hole circle radius 31.5–48.5 mm

PBT-RB1X6AG2SS0AMA0Z
Pressure sensors | PBT | PBT-RB1X6AG2SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 1.6 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Co

GRSE18S-N2427
Photoelectric sensors | GR18 | GRSE18S-N2427 | Functional principle: Through-beam photoelectric sensor | Switching output: NPN | Switching mode: Light/dark switching | Connection type: Male connector M12, 4-pin | Light source: LED | Adjustment: Potentiometer | Communication interface: - | Included with delivery: Fastening nuts (4 x)

SGS4-F108P3PS1W00
Automation light grids | SLG | SGS4-F108P3PS1W00 | Optical light exit: Flat | Aluminum stabilizer: Without stabilizer | Parameterization: None | Beam separation: 40 mm | Cross beam/parallel beam: Parallel beam active | Operating range: 3 m | Detection height: 1,080 mm | Response time: 19 ms

MZC1-2V2PS-KRDS21
Cylinder sensors | MZC1 | MZC1-2V2PS-KRDS21 | Connection type: Cable with plug M8, 3-pin, with knurled nut, 0.15 m | Output function: NO | Electrical wiring: DC 3-wire | Communication interface: -

MAX48N-32V20K10240
Linear encoders | MAX | MAX48N-32V20K10240 | Type: Ø 48 mm 48f7 - IN Cylinder Mounting Ø48H8 | Pipe diameter / Damping zone / End cap: 63 mm / Flat | Supply voltage: 24 V DC (+8 V DC ... +32 V DC) | Communication interface: - / Voltage | Connection type: Connecting cable, 3-wire, 300 mm | Measuring range: 0 mm ... 240 mm | Output signal: 0.25 V DC ... 4.75 V DC

AFM60B-BDPK032768
Absolute encoders | AFS/AFM60 SSI | AFM60B-BDPK032768 | Singleturn or multiturn version: Multiturn | Max. resolution: 15 bit x 12 bit (32,768 x 4,096) | Mechanical design: Blind hollow shaft 10 mm (Front clamp) | Communication interface: SSI, programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Programming interface: Over handheld programming tool, over SOPAS

DBS50E-S5RK00500
Incremental encoders | DBS36/50 | DBS50E-S5RK00500 | Mechanical design: Solid shaft face mount flange 8 mm x 15.5 mm (With flat) | Communication interface: 7 V ... 30 V, Open Collector | Connection type: Cable, 5-wire, universal, 1.5 m | Pulses per revolution: 500

DBS60E-T5AJC1024
Incremental encoders | DBS60 | DBS60E-T5AJC1024 | Mechanical design: Through hollow shaft 12 mm (Front clamp) | Communication interface: 4.5 V ... 5.5 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 0.5 m | Pulses per revolution: 1,024 | Flange type / stator coupling: Axial and radial register pin mounting, for 4 mm register pin

YM2A28-100UA6XLEAX
Connectors and cables | Sensor-actuator cables | YM2A28-100UA6XLEAX | Description: Sensor/actuator cable, shielded | Connection type head A: Male connector, M12, 8-pin, straight, A-coded | Connection type head B: Flying leads | Signal type: Sensor/actuator cable | Cable: 10 m, 8-wire, PUR, halogen-free | Application: Drag chain operation, Zones with oils and lubricants, Robot, Drag chain operation

MLG20N-0440P10501
Automation light grids | MLG-2 | MLG20N-0440P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 20 mm | Operating range: 5 m | Detection height: 440 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

LFP0400-G2NMB
Level sensors | LFP Inox | LFP0400-G2NMB | Communication interface: IO-Link | Process connection: G ¾ A | Probe length: 400 mm | Probe type: Rod probe in hygienic design | Remote amplifier: No | Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V | Connection type: Round connector M12 x 1, 5-pin | Process temperature: –20 °C ... +150 °C | Process pressure: –1 bar ... 16 bar | Housing design: With closed cover | Wetted parts: Stainless steel 1.4404 / 316L, PEEK | Housing material

AFS60A-TDAC065536
Absolute encoders | AFS/AFM60 SSI | AFS60A-TDAC065536 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 65,536 (16 bit) | Mechanical design: Through hollow shaft 10 mm (Front clamp) | Communication interface: SSI, non programmable | Connection type: Male connector, M12, 8-pin, radial