Търсене в каталога
41538 резултата за "SICK" · стр. 816/2077

PBT-RB100SG2SS0AMA0Z
Pressure sensors | PBT | PBT-RB100SG2SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 100 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Conn

OLS20-UB1118140
Contrast sensors | OLS | OLS20-UB1118140 | Communication interface: IO-Link, Modbus® | Light source: LED | Sensing distance: 100 mm | Sensing distance tolerance: ± 10 mm | Switching output: Push-pull: PNP/NPN | Light spot size: 180 mm x 9 mm | Bar code types: Interleaved 2 of 5 | Track color: Orange, green, yellow | Connection type Detail: Plug, M12, 5-pin | Enclosure rating: IP67 | Housing material: Metal

AFS60B-TDPK018000
Absolute encoders | AFS/AFM60 SSI | AFS60B-TDPK018000 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 18,000 | Mechanical design: Through hollow shaft 10 mm (Front clamp) | Communication interface: SSI, programmable | Connection type: Cable, 8-wire, universal, 1.5 m | Programming interface: Over handheld programming tool, over SOPAS

V2D8509R-1MEKEXAF2SXXXX
Image-based code readers | Lector85x | V2D8509R-1MEKEXAF2SXXXX | Variant: Complete device | Regulatory Model: Z6ARAC | Optical focus: Dynamic focus control | Sensor resolution: 4,096 px x 2,176 px (9 MP) | Illumination color: White | Focal length: 25 mm | Ambient operating temperature: 0 °C ... +50 °C | Communication interface: Ethernet, EtherNet/IP™, CAN, Serial, USB, PROFINET

BEF-KHS-L01
Mounting systems | Brackets | BEF-KHS-L01 | Description: Plate L for universal clamp bracket | Material: Steel | Details: Steel, zinc coated | Items supplied: Universal clamp (2022726), mounting hardware | Usable for: W8, W100, W140-2, W150, W160, W9-2, W250, P250, LUT2, KT3, CSM1, G6, W100-2, W250, LUT2, W9-3, W150, CSM, LUTM, G10, W8, P250, KTM Core, KTM Prime

DBS60E-T6EA00100
Incremental encoders | DBS60 | DBS60E-T6EA00100 | Mechanical design: Through hollow shaft 1/2″ (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Male connector, M23, 12-pin, radial | Pulses per revolution: 100 | Flange type / stator coupling: 2-sided stator coupling, slot, screw hole circle 63–83 mm

DBS60E-BDEC00500
Incremental encoders | DBS60 | DBS60E-BDEC00500 | Mechanical design: Blind hollow shaft 10 mm (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Male connector, M12, 8-pin, radial | Pulses per revolution: 500 | Flange type / stator coupling: 2-sided stator coupling, slot, screw hole circle 63–83 mm

C2C-SB06030A10000, C2C-EB06030A10000
Safety light curtains | deTec | C2C-SB06030A10000, C2C-EB06030A10000 | Product version: deTec2 Core IP69K | System part: Pair | Application: Areas with special hygiene requirements | Safety level: PL c, SIL 1, Type 2 | Resolution: 30 mm | Scanning range: 12.5 m | Protective field height: 600 mm | Connection type: Connecting cable, 15 m, flying leads, 5-wire | Enclosure rating: IP65, IP66, IP67, IP69K | Items supplied: Sender in IP69K protective housing with connecting cable, 15 m, receiver in IP

WS/WE24-2V230
Photoelectric sensors | W24 | WS/WE24-2V230 | Sensing range max.: 0 m ... 60 m | Functional principle: Through-beam photoelectric sensor | Switching output: NPN, PNP | Switching mode: Light/dark switching | Connection type: Terminal connection with M16 gland | Adjustment: Potentiometer

DL100-23AA2103
Laser distance sensors | Dx100 | DL100-23AA2103 | Communication interface: Serial | Measuring range: 0.15 m ... 300 m, on “diamond grade” reflective tape | Laser class: 2 | Light source: Laser, red | Minimum response time: 2 ms | Digital output: 2 x push-pull: PNP/NPN | Multifunctional input (MF): 1 x MF1

PBS2-CB6X0SG2SS0Q5A0Z
Pressure sensors | PBS plus | PBS2-CB6X0SG2SS0Q5A0Z | Pressure type: Compound pressure | Pressure unit: bar psi | Measuring range: –1 bar ... 5 bar, –14.5 psi ... 73 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –20 °C ... +85 °C | Seal: Without seal | Communication interface: IO-Link |

DBS60E-T2EK01000
Incremental encoders | DBS60 | DBS60E-T2EK01000 | Mechanical design: Through hollow shaft 8 mm (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 1,000 | Flange type / stator coupling: 2-sided stator coupling, slot, screw hole circle 63–83 mm

DFS25A-B2CAD000900
Incremental encoders | DFS2x | DFS25A-B2CAD000900 | Mechanical design: Solid shaft Servo flange 3/8″ x 19 mm (With flat) | Communication interface: 8 V ... 30 V, TTL, RS-422, non programmable | Connection type: Male connector, MS, 10-pin, radial | Pulses per revolution: 900

SLG10S-050SAKB1K01
Automation light grids | FlexChain | SLG10S-050SAKB1K01 | Device version: FlexChain Guest | Optical light exit: Slim | Beam separation: 10 mm | Operating range: 4 m | Detection height: 500 mm | Length of cable: 1.5 m

PBT-RB600AG2SE0ALA0Z
Pressure sensors | PBT | PBT-RB600AG2SE0ALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 600 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | C

DFS60E-TGEC00200
Incremental encoders | DFS60 | DFS60E-TGEC00200 | Mechanical design: Through hollow shaft 14 mm (Front clamp) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Male connector, M12, 8-pin, radial | Pulses per revolution: 200

DFS60B-S1EK01800
Incremental encoders | DFS60 | DFS60B-S1EK01800 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 1,800

BEF-HA-851D40-LFP1
Mounting systems | Flanges and nozzles | BEF-HA-851D40-LFP1 | Description: Hygienic process connection adapter, conical coupling (DIN 11851), DN 40 with grooved cap nut, material 1.4404 (Ra ≤ 0.8 µm); hygienic in accordance with EHEDG in combination with ASEPTO-STAR k-flex upgrade gaskets from Kieselmann GmbH or SKS gasket set DIN 11851 EHEDG with EPDM or FKM inner gasket from Siersema Komponenten Service (S.K.S.) B.V

DBS60E-BHAAB2048
Incremental encoders | DBS60 | DBS60E-BHAAB2048 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: 4.5 V ... 5.5 V, TTL, RS-422 | Connection type: Male connector, M23, 12-pin, radial | Pulses per revolution: 2,048 | Flange type / stator coupling: Stator coupling, 2-sided, screw hole circle 63 mm

DFS60B-BGEC02000
Incremental encoders | DFS60 | DFS60B-BGEC02000 | Mechanical design: Blind hollow shaft 14 mm (Front clamp) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Male connector, M12, 8-pin, radial | Pulses per revolution: 2,000