PBT-RB040SG1SEFAMA0Z
Pressure sensors | PBT | PBT-RB040SG1SEFAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection

TR10-SLM03P
Safety switches | TR10 Lock | TR10-SLM03P | Locking principle: Power to lock | Locking force FZh: 1,300 N | Coding: Universally coded | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics)

PBT-RB100SG2SS0VMC0Z
Pressure sensors | PBT | PBT-RB100SG2SS0VMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 100 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connec

IME18-12NPSVW2S
Inductive proximity sensors | IME | IME18-12NPSVW2S | Housing: Standard design | Sensing range Sn: 12 mm | Installation type: Non-flush | Electrical wiring: DC 3-wire | Switching output: PNP | Output function: NO | Connection type: Cable, 3-wire, 2 m

Connecting cable for ICL illumination
Connectors and cables | Other connectors and cables | Connecting cable for ICL illumination | Description: Shielded | Connection type head A: Female connector, M8, 4-pin, straight | Connection type head B: Flying leads | Cable: 5 m, 4-wire | Connection systems: Flying leads | Note: For external ICL ring illuminations and dark field light

DFS60B-BDCM01200
Incremental encoders | DFS60 | DFS60B-BDCM01200 | Mechanical design: Blind hollow shaft 10 mm (Front clamp) | Communication interface: 10 V ... 32 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 5 m | Pulses per revolution: 1,200

TR4-SBU10PB
Safety switches | TR4 Direct | TR4-SBU10PB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 25 mm | Connection type Detail: Cable | Length of cable: 10 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

BEF-FL-316G10-BHYG
Mounting systems | Flanges and nozzles | BEF-FL-316G10-BHYG | Description: Weld-in flange/connector for process connection G 1 hygienic flush-mounted | Material: Stainless steel | Details: Stainless steel

DFS60E-BHCM02048
Incremental encoders | DFS60 | DFS60E-BHCM02048 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: 10 V ... 32 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 5 m | Pulses per revolution: 2,048

AHS36A-S7CC016384
Absolute encoders | AHS/AHM36 | AHS36A-S7CC016384 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 16,384 (14 bit) | Mechanical design: Solid shaft face mount flange 3/8″ x 12 mm (With flat) | Communication interface: CANopen, programmable | Connection type: Male connector, M12, 5-pin, universal | Programming interface: Over PLC-Engineering-Tool, over handheld programming tool

WF120-60B410
Fork sensors | WF | WF120-60B410 | Adjustment: Plus/minus button | Light source: LED | Type of light: Infrared light | Fork width/depth: 120 mm, 59 mm | Switching output: PNP/NPN | Switching mode: Light/dark switching | Connection type Detail: Male connector M8, 4-pin | Switching frequency: 10 kHz | Response time: ≤ 100 µs | Enclosure rating: IP65

GTB20G-1IRC116GZZZ
Photoelectric sensors | G20 | GTB20G-1IRC116GZZZ | Sensing range min. / max.: 0.005 m / 3 m | Functional principle: Photoelectric proximity sensor | Functional principle detail: Background suppression | Switching output: Relay, SPDT, electrically isolated | Switching mode: Light/dark switching | Connection type: Cable, 5-wire, 2 m | Light source: LED | Type of light: Visible red light | Housing material: ABS | Adjustment: Potentiometer | Housing: Rectangular

AFM60E-BGLA004096
Absolute encoders | AFS/AFM60 SSI | AFM60E-BGLA004096 | Singleturn or multiturn version: Multiturn | Max. resolution: 12 bit x 12 bit (4,096 x 4,096) | Mechanical design: Blind hollow shaft 14 mm (Front clamp) | Communication interface: SSI, SSI + incremental, non programmable, HTL | Connection type: Male connector, M23, 12-pin, radial

FFUS25-1G1SR
Flow sensors | FFU | FFUS25-1G1SR | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: G 1 ¼ | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

DBS60I-Q4EC02000
Incremental encoders | DBS60 | DBS60I-Q4EC02000 | Mechanical design: Solid shaft Square flange 10 mm x 19 mm (With flat) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Male connector, M12, 8-pin, radial | Pulses per revolution: 2,000 | Flange type / stator coupling: Flange with 4 x hole 5.5 mm | Encoder material / Enclosure rating: Stainless steel V2A / IP67

I2D601M-2MCB71
Machine vision | midiCam2 | I2D601M-2MCB71 | Illumination: To be ordered separately as accessories | Lens: To be ordered separately as accessories, C-mount | Sensor resolution: 1,456 px x 1,088 px (1.58 MP) | Sensor: CMOS monochrome | Sensor used: Sony IMX273

LFPCT-0400N1
Device protection and care | Protective housing | LFPCT-0400N1 | Description: Coaxial tube for LFP with process connection G 3/4, process connection of coaxial tube 3/4" NPT, material 1.4571/316TI, for probe length 400 mm

MLG50N-2350N10501
Automation light grids | MLG-2 | MLG50N-2350N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 50 mm | Operating range: 5 m | Detection height: 2,350 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

DFS60B-S1VA02000
Incremental encoders | DFS60 | DFS60B-S1VA02000 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 32 V, TTL, RS-422 | Connection type: Male connector, M23, 12-pin, radial | Pulses per revolution: 2,000

LFP3200-G1NMB
Level sensors | LFP Inox | LFP3200-G1NMB | Communication interface: IO-Link | Process connection: G ¾ A | Probe length: 3,200 mm | Probe type: Rod probe in hygienic design | Remote amplifier: No | Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V | Connection type: Round connector M12 x 1, 5-pin | Process temperature: –20 °C ... +150 °C | Process pressure: –1 bar ... 16 bar | Housing design: With viewing window made from PMMA (acrylic glass) | Wetted parts: Stainless steel 1.4