Търсене в каталога
41538 резултата за "SICK" · стр. 63/2077

ARS60-F4L08192
Absolute encoders | ARS60 | ARS60-F4L08192 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 8,192 (13 bit) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: Parallel data world | Connection type: Cable, 22-wire, radial, 3 m

FFUS25-1N1SR
Flow sensors | FFU | FFUS25-1N1SR | Nominal width measuring tube: DN 25 | Maximum flow: ≤ 240 l/min | Wetted parts: PPSU, EPDM | Process connection: 1 ¼" NPT | Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, 1 switching input for dosing and counter reset | Process temperature: 0 °C ... +80 °C | Process pressure: ≤ 10 bar

WL2SG-2P3236
Photoelectric sensors | W2 | WL2SG-2P3236 | Functional principle: Photoelectric retro-reflective sensor | Functional principle detail: Without reflector minimum distance (autocollimation/coaxial optics) | Switching output: PNP | Switching mode: Light switching | Connection type: Cable with M8 male connector, 4-pin, 355 mm | Light source: PinPoint LED | Adjustment: Teach-in button | Communication interface: - | Included with delivery: Teach-in male contact

YMRJA8-100EG1MRJA8
Connectors and cables | Industrial Ethernet cables and fieldbus cables | YMRJA8-100EG1MRJA8 | Connection type head A: Male connector, RJ45, 8-pin, straight | Connection type head B: Male connector, RJ45, 8-pin, straight | Signal type: Ethernet, Gigabit Ethernet | Cable: 10 m, 8-wire, PUR, halogen-free | Description: Ethernet, shielded, Gigabit Ethernet | Application: Zones with oils and lubricants

SYS/BOT-URSP4ESUA02NS3
Safety systems | Safe Robotics Area Protection | SYS/BOT-URSP4ESUA02NS3 | Variant: sBot Speed2 – URCap | Product type: System (hardware and software) | Robot controller: Universal Robots: e-Series + UR Series robots | Stopping process of the robot: With speed reduction | Robot restart: Automatic | Interface: Discrete I/Os

MICS3-CBAZ90ZA1P01
Safety laser scanners | microScan3 | MICS3-CBAZ90ZA1P01 | Product version: microScan3 Pro - EFI-pro | Model: Sensor (1094464) including system plug (2086102), pre-mounted on the underside | Integration in the control system: EFI-pro | Protective field range: 9 m | Collision protection field range: 19 m | Scanning angle: 275° | Number of fields: 128 | Connection type: M12

WF80-60B416
Fork sensors | WF | WF80-60B416 | Adjustment: Plus/minus button | Light source: LED | Type of light: Infrared light | Fork width/depth: 80 mm, 59 mm | Switching output: PNP/NPN | Switching mode: Light/dark switching | Connection type Detail: Male connector M8, 4-pin | Switching frequency: 10 kHz | Response time: ≤ 100 µs | Enclosure rating: IP65

YF2A68-100XXXXLEAX
Connectors and cables | Sensor-actuator cables | YF2A68-100XXXXLEAX | Description: Shielded | Connection type head A: Female connector, M12, 8-pin, straight | Connection type head B: Flying leads | Cable: 10 m, 8-wire, PUR, halogen-free | Application: Drag chain operation, Zones with oils and lubricants

Pushbutton for laser alignment aid, M12, 8-pin
Commissioning aids and test equipment | Configuration devices | Pushbutton for laser alignment aid, M12, 8-pin | Description: The M12 8-pin pushbutton makes it possible to switch the laser alignment aid integrated in the deTec4 sender on and off.

MZT8-2V8-N-KWDS03
Cylinder sensors | MZT8 ATEX | MZT8-2V8-N-KWDS03 | Connection type: Cable, 2-wire, ferrules, 10 m | Electrical wiring: DC 2-wire | Communication interface: -

WL2SG-2F3235
Photoelectric sensors | W2 | WL2SG-2F3235 | Functional principle: Photoelectric retro-reflective sensor | Functional principle detail: Without reflector minimum distance (autocollimation/coaxial optics) | Switching output: PNP | Switching mode: Dark switching | Connection type: Cable with M8 male connector, 4-pin, 200 mm | Light source: PinPoint LED | Adjustment: Wire/pin | Communication interface: -

IMP05-01BPSVU2S
Inductive proximity sensors | IMP | IMP05-01BPSVU2S | Special applications: Hydraulic application | Sensing range Sn: 1 mm | Installation type: Flush | Electrical wiring: DC 3-wire | Switching output: PNP | Output function: NO | Connection type: Cable, 3-wire, 2 m | Special features: High pressure resistant, Temperature resistance

E100-A2A22S05A
Safety switches | E100 | E100-A2A22S05A | Type of connection cable: Straight | Plus/minus button: no | Length of cable: 5 m

WSE280-2P4331
Photoelectric sensors | W280 | WSE280-2P4331 | Functional principle: Through-beam photoelectric sensor | Switching output: PNP | Switching mode: Light/dark switching | Connection type: Cable gland | Light source: LED | Adjustment: Potentiometer | Communication interface: - | Included with delivery: Mounting bracket BEF-W280

IME2S18-05B4DC0
Safety switches | IME2S | IME2S18-05B4DC0 | Design: Cylindrical | Sensing range Sn: 5 mm | Dimensions: M18 x 69 mm | Thread length: 44.2 mm | Installation type: Flush | Connection type Detail: Male connector M12, 4-pin | Type of output: Self-monitoring semiconductor outputs (OSSDs) | Performance level: PL d

SRS50-HWA0-K21
Motor feedback systems | SRS/SRM50 | SRS50-HWA0-K21 | Communication interface: HIPERFACE® | Model: Absolute Singleturn | Type: Stand-alone | Sine/cosine periods per revolution: 1,024 | Safety system: no | Mechanical design: Solid shaft, face mount flange | Connection type: Male connector, M23, 12-pin, radial | Technology: Optical | Operating temperature range: –30 °C ... +85 °C

YF2A25-200UB6XLEAX
Connectors and cables | Sensor-actuator cables | YF2A25-200UB6XLEAX | Description: Sensor/actuator cable, shielded | Connection type head A: Female connector, M12, 5-pin, straight, A-coded | Connection type head B: Flying leads | Signal type: Sensor/actuator cable | Cable: 20 m, 5-wire, PUR, halogen-free | Application: Drag chain operation, Zones with oils and lubricants, Robot, Drag chain operation

C4P-SA15011A00, C4P-EA15011C00
Safety light curtains | deTec | C4P-SA15011A00, C4P-EA15011C00 | Product version: deTec4 | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Resolution: 14 mm | Scanning range: 20 m | Protective field height: 1,500 mm | Connection type: Depending on system plug (M12 male connector, 5-pin or 8-pin) | Extension connection: Depending on system plug (without extension connection or with M12 female connector, 5-pin) | Enclosure rating: IP65, IP67 | I

MLG10N-2540N10501
Automation light grids | MLG-2 | MLG10N-2540N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 10 mm | Operating range: 5 m | Detection height: 2,540 mm | Length of cable: 0.22 m, 0.21 m | Response time: 21 ms | Software feature (default setting - see technical data/features): 01

CSS-WBF114115AA10Z
Color sensors | CSS/CSX High Speed | CSS-WBF114115AA10Z | Light source: LED | Housing design: Small | Communication interface: IO-Link | Sensing distance: 13 mm | Switching output: Push-pull: PNP/NPN | Light spot size: 2 mm x 4 mm | Light spot direction: Vertical | Light emission: Long side of housing | Connection type Detail: Plug, M12, 5-pin