PTAM-1XXXXLULMZX
Pressure sensors | PTA | PTAM-1XXXXLULMZX | Pressure type: Gauge pressure | Pressure unit: bar psi | Measuring chamber type: Metallic pressure measuring cell | Measuring range: 0 bar ... 100 bar, 0 psi ... 1,450 psi | Accuracy: ≤ ± 0.3 %, of the span | Process connection: G ½ (ISO 228-1) | Process temperature: –20 °C ... +130 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP66, IP67, IP69 | Supply voltage: 12

AFM60B-BHAL008192
Absolute encoders | AFS/AFM60 SSI | AFM60B-BHAL008192 | Singleturn or multiturn version: Multiturn | Max. resolution: 13 bit x 12 bit (8,192 x 4,096) | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI, non programmable | Connection type: Cable, 8-wire, universal, 3 m

DFS60B-TDPM10000
Incremental encoders | DFS60 | DFS60B-TDPM10000 | Mechanical design: Through hollow shaft 10 mm (Front clamp) | Communication interface: 4.5 V ... 32 V, TTL, HTL, programmable | Connection type: Cable, 8-wire, universal, 5 m | Pulses per revolution: 10,000

PBT-RM1X0SR1SS0AMA0Z
Pressure sensors | PBT | PBT-RM1X0SR1SS0AMA0Z | Pressure type: Gauge pressure | Pressure unit: MPa | Measuring range: 0 MPa ... 1 MPa | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: R ¼ (ISO 7) | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection typ

GRF18S-E234LV
Level sensors | GRF18S | GRF18S-E234LV | Communication interface: - | Process connection: G ½ | Remote amplifier: No | Output signal: 1 x NPN | Connection type: M12 round connector x 1, 4-pin | Process temperature: –10 °C ... +55 °C | Process pressure: –0.5 bar ... 20 bar | Switching mode: NO | Wetted parts: FPM, Stainless steel 1.4404 / 316L, polysulfon | Housing material: Stainless steel 1.4404 / 316L | Enclosure rating: IP67, IP69 | Display: no | PWIS-cleaned: no | Bluetooth: no

ARS60-FDK32768
Absolute encoders | ARS60 | ARS60-FDK32768 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,768 (15 bit) | Mechanical design: Through hollow shaft 12 mm (Front clamp) | Communication interface: Parallel data world | Connection type: Cable, 22-wire, radial, 1.5 m

MWS075-12C111P101000
Measuring wheel encoders | MWS075 | MWS075-12C111P101000 | Measuring wheel circumference: 200 mm | Measuring wheel surface: O-ring NBR70 | Communication interface: 7 V ... 30 V, Incremental, HTL, Push pull | Supply voltage: 7 V ... 30 V | Mounted encoder: DBS36/50, DBS50E-S5EP01000, 1062886 | Connection type: Cable, 8-wire, with male connector, M12, 8-pin, universal, 0.5 m | Resolution in pulses/mm: 5

V2D632R-MXCXB0
Image-based code readers | Lector63x | V2D632R-MXCXB0 | Variant: Main unit | Optical focus: Adjustable focus (manual) | Sensor resolution: 1,600 px x 1,200 px (1.9 MP) | Communication interface: Ethernet, PROFINET, EtherNet/IP™, Serial, CAN, PROFIBUS DP | Cold storage applications: no | Note: Additional accessories may be necessary for some communication interfaces (details available online)

Node for voltage supply
Connectors and cables | Other connectors and cables | Node for voltage supply

M2C-SB0250LA10, M2C-EB02500A10
Safety light-beam sensors | deTem | M2C-SB0250LA10, M2C-EB02500A10 | Product version: deTem2 Core IP69K | Functional principle: Sender/receiver | System part: Pair | Application: Areas with special hygiene requirements | Safety level: PL c, SIL 1, Type 2 | Functions: Protective operation | Scanning range: 15.5 m | Number of beams: 2 | Beam separation: 500 mm | Connection type: Connecting cable, 5-wire | Integrated laser alignment aid: no | Enclosure rating: IP65, IP66, IP67, IP69K | Items suppli

DFS60A-S4EK01000
Incremental encoders | DFS60 | DFS60A-S4EK01000 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 1,000

AFS60S-BCSL262144
Safety encoders | AFS/AFM60S Pro | AFS60S-BCSL262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 262,144 (18 bit) | Mechanical design: Blind hollow shaft 3/8″ (with feather key groove) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, radial, 3 m

ARS60-J4R00400
Absolute encoders | ARS60 | ARS60-J4R00400 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 400 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: Parallel data world | Connection type: Cable, 22-wire, axial, 1.5 m

PBT-RB060SG1SENAMA0Z
Pressure sensors | PBT | PBT-RB060SG1SENAMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection t

PBSH-CB010SHGEEBMA0Z
Pressure sensors | PBS Hygienic | PBSH-CB010SHGEEBMA0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 9 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G 1 hygienic flush-mounted | Process temperature: –20 °C ... +125 °C | Seal: EPDM | Communication interface: - | Output signal: 1 x PNP + 4 mA ... 20 mA | Connection type

IMM05-0B8NOVT0S
Inductive proximity sensors | IMM | IMM05-0B8NOVT0S | Housing: Standard design | Sensing range Sn: 0.8 mm | Installation type: Flush | Electrical wiring: DC 3-wire | Switching output: NPN | Output function: NC | Connection type: Connector M8, 3-pin | Special features: Visual adjustment indicator

DBS60E-BHEJC1024
Incremental encoders | DBS60 | DBS60E-BHEJC1024 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 0.5 m | Pulses per revolution: 1,024 | Flange type / stator coupling: Axial and radial register pin mounting, for 4 mm register pin

DBS60E-TFAJC1024
Incremental encoders | DBS60 | DBS60E-TFAJC1024 | Mechanical design: Through hollow shaft 1/2″ (Front clamp) | Communication interface: 4.5 V ... 5.5 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 0.5 m | Pulses per revolution: 1,024 | Flange type / stator coupling: Axial and radial register pin mounting, for 4 mm register pin

DAXLAN-0210BA080000D00
Linear encoders | DAX | DAXLAN-0210BA080000D00 | Design: DAX Low Profile | Communication interface: - / Current | Current output: 4 mA ... 20 mA | Connection type: Male connector, M12, 5-pin | Measurement range: 0 mm ... 210 mm | Supply voltage: 24 V DC (± 20%) | Sequence of signals: Rising | Unusable range (zero zone/damping zone): 55 mm / 63 mm | Magnet type: Small block magnet MAG-B-180-01

WSE12-3V1111S04
Photoelectric sensors | W12-3 | WSE12-3V1111S04 | Sensing range max.: 0 m ... 20 m | Functional principle: Through-beam photoelectric sensor | Switching output: PNP | Switching mode: Dark switching | Connection type: Cable, 4-wire, 2 m | Light source: LED | Type of light: Infrared light | Adjustment: Potentiometer | Housing: Rectangular