LFH-EW4X0G1AS15ST0
Level sensors | LFH | LFH-EW4X0G1AS15ST0 | Communication interface: - | Process connection: Without process connection | Remote amplifier: No | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: PUR cable connection | Process temperature: –10 °C ... +50 °C | Process pressure: 0 mH2O ... 4 mH2O | Wetted parts: Stainless steel 1.4404 / 316L, PA | Housing material: Stainless steel 1.4404 / 316L | Enclosure rating: IP68 | Display: no | PWIS-cleaned: no | Bluetooth: no | Additional function: Te

MLG10N-1340C10501
Automation light grids | MLG-2 | MLG10N-1340C10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 10 mm | Operating range: 5 m | Detection height: 1,340 mm | Length of cable: 0.22 m, 0.21 m | Response time: 11.7 ms | Software feature (default setting - see technical data/features): 01

CLV640-0120
Fixed mount barcode scanners | CLV64x | CLV640-0120 | Optical focus: Dynamic focus control | Communication interface: Ethernet, PROFINET, EtherNet/IP™, EtherCAT®, Serial, CAN, CANopen, PROFIBUS DP | Type: Rotary angle variant single port (12-pin) | Max. reading distance: 840 mm | Code resolution: 0.2 mm ... 1 mm | Code printing process: Label (printed codes) | Sensor type: Line scanner | Window material: Glass | Cold storage applications: no | Enclosure rating: IP65

DFS60B-THEK04000
Incremental encoders | DFS60 | DFS60B-THEK04000 | Mechanical design: Through hollow shaft 15 mm (Front clamp) | Communication interface: 10 V ... 32 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 4,000

DBS60E-TFEA00100
Incremental encoders | DBS60 | DBS60E-TFEA00100 | Mechanical design: Through hollow shaft 1/2″ (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Male connector, M23, 12-pin, radial | Pulses per revolution: 100 | Flange type / stator coupling: 2-sided stator coupling, slot, screw hole circle 63–83 mm

BAS3502-E
Object detection systems | Backup Assistance System | BAS3502-E | Areas of application: Indoor and outdoor areas (8 m) | Vehicle: Electric forklifts | Number of LiDAR sensors: 2 | Functions: Visual and acoustic collision warning

MZT7-03VNS-KWB
Cylinder sensors | MZT7 | MZT7-03VNS-KWB | Connection type: Cable, 3-wire, stripped | Output function: NO | Overrun distance, typ.: 10 mm | Enclosure rating: IP65, IP67 | Supply voltage: 10 V DC ... 30 V DC | Electrical wiring: DC 3-wire

WL9LG-3P1152
Photoelectric sensors | W9 | WL9LG-3P1152 | Functional principle: Photoelectric retro-reflective sensor | Functional principle detail: Without reflector minimum distance (autocollimation/coaxial optics) | Switching output: PNP | Switching mode: Light/dark switching | Connection type: Cable, 4-wire, 2 m | Light source: Laser | Adjustment: Teach-in button | Laser class: 1 | Communication interface: -

RSB1-0540B180180HZ3CZZZZZZ
Photoelectric sensors | Roller Sensor Bar | RSB1-0540B180180HZ3CZZZZZZ | Sensing range min. / max.: 2 mm / 300 mm | Functional principle: Photoelectric proximity sensor | Functional principle detail: Energetic | Length of Sensor Bar: 540 mm | Number of beams: 2 | Beam separation: 180 mm | Switching output: PNP: open collector | Connection type: Cable with connector M8, 4-pin, with knurled nut | Length of cable: 300 mm | Light source: LED | Type of light: Infrared light | Housing material: Alumin

MQ10-60APSKQDS02
Magnetic sensors | MQB | MQ10-60APSKQDS02 | Sensing range Sn: 60 mm | Cuboid shape (W x H x D): 10 mm x 28 mm x 16 mm | Switching output: PNP | Connection type: Cable with connector M12, 3-pin, 1 m | Housing material: Plastic | Output function: NO

C4P-SA06031A00, C4P-EA06031C00
Safety light curtains | deTec | C4P-SA06031A00, C4P-EA06031C00 | Product version: deTec4 | System part: Pair | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Resolution: 30 mm | Scanning range: 30 m | Protective field height: 600 mm | Connection type: Depending on system plug (M12 male connector, 5-pin or 8-pin) | Extension connection: Depending on system plug (without extension connection or with M12 female connector, 5-pin) | Enclosure rating: IP65, IP67 | Ite

TBS-1BSG11506NM
Temperature sensors | TBS | TBS-1BSG11506NM | Temperature measuring range: –20 °C ... +80 °C | Process connection: Thread G ¼ A | Insertion length/diameter of probe: 150 mm / 6 mm | Seal: NBR | Output signal: 1 x PNP + 4 mA ... 20 mA | Connection type: M12 round connector x 1, 4-pin | Enclosure rating: IP65, IP67 | Communication interface: -

DAXTAN-0150RA1J0100D00
Linear encoders | DAX | DAXTAN-0150RA1J0100D00 | Design: DAX Threaded | Communication interface: - / Current | Current output: 4 mA ... 20 mA | Connection type: Male connector, M12, 5-pin | Measurement range: 0 mm ... 150 mm | Supply voltage: 24 V DC (± 20%) | Sequence of signals: Rising | Unusable range (zero zone/damping zone): 50 mm / 63 mm | Magnet type: Ring magnet MAG-O-330-01 | Thread offset: Without thread offset | Thread shape: M18 x 1.5

IME18-08BPOZC0S
Inductive proximity sensors | IME | IME18-08BPOZC0S | Housing: Standard design | Sensing range Sn: 8 mm | Installation type: Flush | Electrical wiring: DC 3-wire | Switching output: PNP | Output function: NC | Connection type: Male connector M12, 4-pin

PBT-RBX20SGTSFNVMC0Z
Pressure sensors | PBT | PBT-RBX20SGTSFNVMC0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.2 bar | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –20 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection ty

SSL-0J08-G03MES01
Connectors and cables | Other connectors and cables | SSL-0J08-G03MES01 | Description: Gigabit Ethernet, unshielded | Connection type head A: Male connector, RJ45 | Connection type head B: Male connector, RJ45 | Signal type: Gigabit Ethernet | Cable: 3 m

WL9M4-3V1132
Photoelectric sensors | W9 | WL9M4-3V1132 | Functional principle: Photoelectric retro-reflective sensor | Functional principle detail: Without reflector minimum distance (autocollimation/coaxial optics) | Switching output: PNP | Switching mode: Dark switching | Connection type: Cable, 4-wire, 2 m | Light source: PinPoint LED | Adjustment: Teach-in button | Communication interface: -

deTec4 Core Set 30/1350
Safety light curtains | deTec | deTec4 Core Set 30/1350 | Product version: deTec4 Core | System part: Set | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Resolution: 30 mm | Scanning range: 15 m | Protective field height: 1,350 mm | Connection type: Plug, M12, 5-pin | Enclosure rating: IP65, IP67 | Items supplied: Sender, receiver, 4 FlexFix brackets, 4 QuickFix brackets, 2 connecting cables, 5 m, test rod with diameter corresponding to the resolution of the sa

BEF-MRA-G130-SPCR
Mounting systems | Brackets | BEF-MRA-G130-SPCR | Description: Spacer for front mounting of the wire rope hoist crane mechanics: MRA-G130*

DBS60E-BHEKD1024
Incremental encoders | DBS60 | DBS60E-BHEKD1024 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: 10 V ... 27 V, HTL, Push pull | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 1,024 | Flange type / stator coupling: 1-sided stator coupling, slot, screw hole circle radius 31.5–48.5 mm