PFT-SABX60SGDSEAAMSSZ
Pressure sensors | PFT | PFT-SABX60SGDSEAAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –40 °C ... +125 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SRB025SGDSSAALSSZ
Pressure sensors | PFT | PFT-SRB025SGDSSAALSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B (EN 837) | Pressure port: Stan

PFT-SRB600AN1SSAAMSSZ
Pressure sensors | PFT | PFT-SRB600AN1SSAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 600 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

ARS60-AAA32768
Absolute encoders | ARS60 | ARS60-AAA32768 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,768 (15 bit) | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, radial

PFT-SRB040AG2SEAVLSSZ
Pressure sensors | PFT | PFT-SRB040AG2SEAVLSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressure port

PFT-SRP100SGDSSAA1SSZ
Pressure sensors | PFT | PFT-SRP100SGDSSAA1SSZ | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 100 psi | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B (EN 837) | Pressure port: Sta

PFT-SAB1X0SN1SSAULSSF
Pressure sensors | PFT | PFT-SAB1X0SN1SSAULSSF | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 1 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: ¼'' NPT | Pressure port: Standard

PFT-FAB4X0AF2OHCVMSSZ
Pressure sensors | PFT | PFT-FAB4X0AF2OHCVMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +150 °C | Seal: FKM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PHT-RB025SVF0S0AFT0Z
Pressure sensors | PHT | PHT-RB025SVF0S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Varivent connection type F | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply vol

PHT-RB025S520S0AMS0Z
Pressure sensors | PHT | PHT-RB025S520S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Conical coupling (DIN 11851) DN 25 with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

PFT-SCB1X6AGDSEAAMSSZ
Pressure sensors | PFT | PFT-SCB1X6AGDSEAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 0.6 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B (EN 837) | Pressure port

PHT-RB025S640S0ALS0Z
Pressure sensors | PHT | PHT-RB025S640S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 40 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connec

PFT-SAB1X6AGDSSAAMSSZ
Pressure sensors | PFT | PFT-SAB1X6AGDSSAAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 1.6 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B (EN 837) | Pressure port:

ARS60-BDL00360
Absolute encoders | ARS60 | ARS60-BDL00360 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 360 | Mechanical design: Through hollow shaft 12 mm (Front clamp) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 3 m

PFT-SRP030SGDSSAVMSSZ
Pressure sensors | PFT | PFT-SRP030SGDSSAVMSSZ | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 30 psi | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ½ B (EN 837) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

PHT-RB010ST10S0AFT0Z
Pressure sensors | PHT | PHT-RB010ST10S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 10 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply vol

PFT-SRB100SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SRB100SG1SSAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 100 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure port:

WLL180T-N474
Fiber-optic sensors | WLL180 | WLL180T-N474 | Device type: Fiber-optic amplifier | Device type detail: Stand-alone | Switching output: NPN | Connection type: Male connector M8, 4-pin | Type of light: Infrared light | Adjustment: Menu-controlled, Teach-in button, cable | Display: 7-segment, 8-digit | Special features: Glass fibers necessary | Included with delivery: BEF-WLL180 mounting bracket

PFT-FRB400SF2OSSAMSSZ
Pressure sensors | PFT | PFT-FRB400SF2OSSAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 400 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure port

PFT-SRP5X0SN1SEAA5SSZ
Pressure sensors | PFT | PFT-SRP5X0SN1SEAA5SSZ | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 5 psi | Accuracy: ≤ ± 0.5 %, of the span | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: –40 °C ... +125 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Flying leads, 3 m, IP68 | Supply voltage: 10 V DC ... 30 V DC