PFT-SABX40AG2SEAALSSZ
Pressure sensors | PFT | PFT-SABX40AG2SEAALSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressure

PHT-RB6X0SD30S0AFT0Z
Pressure sensors | PHT | PHT-RB6X0SD30S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 32 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply voltage

PHT-RB1X0S650S0AMS0Z
Pressure sensors | PHT | PHT-RB1X0S650S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 1 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

PFT-SRB250AG1SSAAMSSZ
Pressure sensors | PFT | PFT-SRB250AG1SSAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure port

ARS60-A4M08192
Absolute encoders | ARS60 | ARS60-A4M08192 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 8,192 (13 bit) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 5 m

PFT-SRBX60SG1SSAVMSSZ
Pressure sensors | PFT | PFT-SRBX60SG1SSAVMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 14 V DC ... 30 V DC

ARS60-A4B32767
Absolute encoders | ARS60 | ARS60-A4B32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, axial

ARS60-A1A08129
Absolute encoders | ARS60 | ARS60-A1A08129 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 8,129 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, radial

ARS60-AAN08192
Absolute encoders | ARS60 | ARS60-AAN08192 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 8,192 (13 bit) | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 10 m

PFT-SAB1X6AN1SSAALSSZ
Pressure sensors | PFT | PFT-SAB1X6AN1SSAALSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 1.6 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: ¼'' NPT | Pressure port: Standa

PFT-SABX25AG1SSAAMSSF
Pressure sensors | PFT | PFT-SABX25AG1SSAAMSSF | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC | Specialty: Free from oil and

PFT-FRBX25SF1OHCAMSSL
Pressure sensors | PFT | PFT-FRBX25SF1OHCAMSSL | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressure por

PFT-FAB016AF2OSSAMSSZ
Pressure sensors | PFT | PFT-FAB016AF2OSSAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 16 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

ARS60-A1K32767
Absolute encoders | ARS60 | ARS60-A1K32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 1.5 m

PHT-RB2X5ST10SEVFZ0Z
Pressure sensors | PHT | PHT-RB2X5ST10SEVFZ0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 2.5 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: Field housing, IP67 | Supply voltage: 14

AFS60A-BKNB262144
Absolute encoders | AFS/AFM60 Ethernet | AFS60A-BKNB262144 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 262,144 (18 bit) | Mechanical design: Blind hollow shaft 1/4″ (Front clamp) | Communication interface: PROFINET, programmable | Connection type: Male connector, 1x, M12, 4-pin, axial, Female connector, 2x, M12, 4-pin, axial | Programming interface: Over PLC-Engineering-Tool

PFT-FRM25MAF1OSSALSSZ
Pressure sensors | PFT | PFT-FRM25MAF1OSSALSSZ | Pressure type: Gauge pressure | Pressure unit: MPa | Measuring range: 0 MPa ... 0.025 MPa | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G 1 B flush-mounted | Pressure port: Front-flush membrane | Process temperature: –30 °C ... +100 °C | Seal: NBR | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB1X0SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCB1X0SG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 0 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure por

PFT-SCP015SN1SSAAMSSZ
Pressure sensors | PFT | PFT-SCP015SN1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: psi | Measuring range: –30 inHg ... 0 psi | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: ¼'' NPT | Pressure port: Standa

ARS60-BDA00360