Търсене в каталога
41538 резултата за "SICK" · стр. 1985/2077

PFT-SRB060AG1NSAAMSSZ
Pressure sensors | PFT | PFT-SRB060AG1NSAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: 0.3 mm pressure port | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

ARS60-A1L32767
Absolute encoders | ARS60 | ARS60-A1L32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 3 m

PHT-RBX60ET20S0ALS0Z
Pressure sensors | PHT | PHT-RBX60ET20S0ALS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.6 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A

ARS60-AAL32767
Absolute encoders | ARS60 | ARS60-AAL32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 3 m

ARS60-AAS32768
Absolute encoders | ARS60 | ARS60-AAS32768 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,768 (15 bit) | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI | Connection type: Cable, 11-wire, axial, 3 m

PFT-FRB060SF2OSSALSSZ
Pressure sensors | PFT | PFT-FRB060SF2OSSALSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 60 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure port:

PFT-FRB040SF2OHCAMSSZ
Pressure sensors | PFT | PFT-FRB040SF2OHCAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure port:

PFT-SRM025SG1SEAAMSSZ
Pressure sensors | PFT | PFT-SRM025SG1SEAAMSSZ | Pressure type: Gauge pressure | Pressure unit: MPa | Measuring range: 0 MPa ... 25 MPa | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure port:

PFT-SRB250SG1SSAVLSSZ
Pressure sensors | PFT | PFT-SRB250SG1SSAVLSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 250 bar | Accuracy: ≤ ± 0.5 %, of the span | Process connection: G ¼ A (ISO 1179-2) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 14 V DC ... 30 V DC

PFT-SRB400AG2SEAVMSSZ
Pressure sensors | PFT | PFT-SRB400AG2SEAVMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 400 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ female (EN 837) | Pressure por

PFT-SAB2X5SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SAB2X5SG1SSAAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 2.5 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure po

PFT-FAB4X0AF2OSSAMSSZ
Pressure sensors | PFT | PFT-FAB4X0AF2OSSAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure po

PFT-FCP075SF2OHCAMSSZ
Pressure sensors | PFT | PFT-FCP075SF2OHCAMSSZ | Pressure type: Compound pressure | Pressure unit: psi | Measuring range: –30 inHg ... 60 psi | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure

PHT-RB4X0ET10S0AMS0Z
Pressure sensors | PHT | PHT-RB4X0ET10S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 4 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin,

ARS60-A1A00720
Absolute encoders | ARS60 | ARS60-A1A00720 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 720 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, radial

ARS60-A1A32767
Absolute encoders | ARS60 | ARS60-A1A32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, radial

PFT-SRBX10SR1SEAAMSSZ
Pressure sensors | PFT | PFT-SRBX10SR1SEAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.1 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: R ¼ (ISO 7) | Pressure port: Standa

MWS120-32N2NF18X12
Measuring wheel encoders | MWS120 | MWS120-32N2NF18X12 | Measuring wheel circumference: 500 mm | Measuring wheel surface: O-ring NBR70 | Communication interface: 10 V DC ... 30 V DC, PROFINET | Supply voltage: 10 V DC ... 30 V DC | Mounted encoder: AFM60 PROFINET, AFM60A-S4NB018x12, 1059039 | Connection type: Male connector, 1x, M12, 4-pin, axial, Female connector, 2x, M12, 4-pin, axial

PHT-RB025SD40S0AFT0Z
Pressure sensors | PHT | PHT-RB025SD40S0AFT0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 32676) DN 40 | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: Field housing, IP67 | Supply voltag

PFT-SCA100SG1SEAAMSSZ
Pressure sensors | PFT | PFT-SCA100SG1SEAAMSSZ | Pressure type: Compound pressure | Pressure unit: mbar | Measuring range: –100 mbar ... 0 mbar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressur