PHT-CB6X0ST10SEALS0Z
Pressure sensors | PHT | PHT-CB6X0ST10SEALS0Z | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 5 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 1 ½" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: EPDM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP

PFT-FRB016SF2OSSALSSZ
Pressure sensors | PFT | PFT-FRB016SF2OSSALSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 16 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ½ B flush mounted | Pressure port:

WLL180T-P435
Fiber-optic sensors | WLL180 | WLL180T-P435 | Device type: Fiber-optic amplifier | Device type detail: Stand-alone | Switching output: PNP | Connection type: Cable, 4-wire | Type of light: Visible red light | Adjustment: Menu-controlled, Teach-in button, cable | Display: 7-segment, 8-digit | Included with delivery: BEF-WLL180 mounting bracket

ARS60-A4N32767
Absolute encoders | ARS60 | ARS60-A4N32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 10 m

LD-MRS400001S01
LiDAR sensors | LD-MRS | LD-MRS400001S01 | Application: Outdoor, Indoor | Integrated application: Object tracking | Working range: 0.5 m ... 320 m | Horizontal aperture angle: 85°, Working range with 4 scan layers, 25° extension of working range to a total of 110° with 2 scan layers | Vertical aperture angle: 3.2° | Amount of evaluated echoes: 3 | Scanning frequency: 12.5 Hz ... 50 Hz, object tracking at 12.5 Hz | Enclosure rating: IP69K | Weight: 1 kg

ARS60-AAK32767
Absolute encoders | ARS60 | ARS60-AAK32767 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 32,767 | Mechanical design: Blind hollow shaft 15 mm (Front clamp) | Communication interface: SSI | Connection type: Cable, 11-wire, radial, 1.5 m

PHT-RB6X0S650S0AMS0Z
Pressure sensors | PHT | PHT-RB6X0S650S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 6 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Coupling (DIN 11864-1) DN 50 form A with union nut | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round

LMS153-10100
LiDAR sensors | LMS1xx | LMS153-10100 | Working range: 0.5 m ... 50 m | Enclosure rating: IP67 | Color: Signal white (RAL 9003) | Integrated application: Field evaluation | Connection type: 1 x M12 round connector | Scanning frequency: 25 Hz, 50 Hz

ARS60-A4A00512
Absolute encoders | ARS60 | ARS60-A4A00512 | Singleturn or multiturn version: Singleturn | Number of steps per revolution: 512 (9 bit) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: SSI | Connection type: Male connector, M23, 12-pin, radial

PFT-FRB1X6SF1OHCAMSSZ
Pressure sensors | PFT | PFT-FRB1X6SF1OHCAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 1.6 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressure port

COD-2000S1A1
Device protection and care | Protective housing | COD-2000S1A1 | Description: 2 FlexFix brackets required per column device. You need two column devices to mount the sender and receiver. See mounting instructions (8022834). | Material: Aluminum | Suitable for: Column device COD for light grid MLG-2

PFT-SAB025SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SAB025SG1SSAAMSSZ | Pressure type: Absolute pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure por

PHT-RB1X0ET20S0AMS0Z
Pressure sensors | PHT | PHT-RB1X0ET20S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 1 bar | Accuracy: ≤ ± 0.25 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Tri-Clamp 2" (DIN 32676) | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP

PFT-FRBX25SF1OSSALSSZ
Pressure sensors | PFT | PFT-FRBX25SF1OSSALSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressure por

PHT-RBX40S740S0AMS0Z
Pressure sensors | PHT | PHT-RBX40S740S0AMS0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 0.5 %, of the span (optional 0.25 % of span (adjusted in vertical mounting position with lower pressure connection)) | Process connection: Clamp (DIN 11864-3) DN 40 form A | Process temperature: –20 °C ... +150 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1,

PFT-SRB160AG2SEAAMSSZ
Pressure sensors | PFT | PFT-SRB160AG2SEAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 160 bar | Accuracy: ≤ ± 0.25 %, of the span | Process connection: G ¼ female (EN 837) | Pressure port: Standard | Process temperature: –40 °C ... +125 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

PFT-SCB016SG1SSAAMSSZ
Pressure sensors | PFT | PFT-SCB016SG1SSAAMSSZ | Pressure type: Compound pressure | Pressure unit: bar | Measuring range: –1 bar ... 15 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G ¼ A (ISO 1179-2) | Pressure po

PFT-FRBX40SF1OSSALSSZ
Pressure sensors | PFT | PFT-FRBX40SF1OSSALSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.4 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: G 1 B flush-mounted | Pressure port

WLL180T-E232
Fiber-optic sensors | WLL180 | WLL180T-E232 | Device type: Fiber-optic amplifier | Device type detail: Expansion unit | Switching output: NPN | Connection type: Cable, 2-wire | Type of light: Visible red light | Adjustment: Menu-controlled, Teach-in button, cable | Display: 7-segment, 8-digit | Included with delivery: BEF-WLL180 mounting bracket

S30B-3011CA