MLG10N-2990C10501
Automation light grids | MLG-2 | MLG10N-2990C10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 10 mm | Operating range: 5 m | Detection height: 2,990 mm | Length of cable: 0.22 m, 0.21 m | Response time: 24.4 ms | Software feature (default setting - see technical data/features): 01

YF2A13-200VB1XLEAX
Connectors and cables | Sensor-actuator cables | YF2A13-200VB1XLEAX | Description: Sensor/actuator cable, unshielded | Connection type head A: Female connector, M12, 3-pin, straight, A-coded | Connection type head B: Flying leads | Signal type: Sensor/actuator cable | Cable: 20 m, 3-wire, PVC | Application: Uncontaminated zones, Zones with chemicals

WIV-V180-T400
Reflectors and optics | Mirror | WIV-V180-T400 | Description: 90° angle attachment for VS/VE180, VL180 unpolarized and VT180 with 400 mm range, temperature –25 ... +60°C

AFM60S-SJSS262144
Safety encoders | AFS/AFM60S Pro | AFM60S-SJSS262144 | Safety integrity level: SIL 3 (IEC 61508, IEC 61800-5-3) | Performance level: PL e (EN ISO 13849-1) | Singleturn or multiturn version: Multiturn | Max. resolution: 18 bit x 12 bit (262,144 x 4,096) | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (with feather key) | Communication interface: SSI, SSI + Sin/Cos, programmable | Connection type: Cable, 12-wire, axial, 3 m

PBT-RP160SN1SS0UMA0Z
Pressure sensors | PBT | PBT-RP160SN1SS0UMA0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 160 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 5 V, 3-wire | Connection type: M1

DFS60E-S1AM01000
Incremental encoders | DFS60 | DFS60E-S1AM01000 | Mechanical design: Solid shaft Servo flange 6 mm x 10 mm (With flat) | Communication interface: 4.5 V ... 5.5 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 5 m | Pulses per revolution: 1,000

DFS60B-S4CK06600
Incremental encoders | DFS60 | DFS60B-S4CK06600 | Mechanical design: Solid shaft face mount flange 10 mm x 19 mm (With flat) | Communication interface: 10 V ... 32 V, TTL, RS-422 | Connection type: Cable, 8-wire, universal, 1.5 m | Pulses per revolution: 6,600

PBST-RB025SG1SSFQMA0Z
Pressure sensors | PBST | PBST-RB025SG1SSFQMA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 25 bar | Accuracy: ≤ ± 0.5 % | Process connection: G ¼ A (ISO 1179-2) | Pressure port: M5 internal thread for pressure spike restrictor | Process temperature: –25 °C ... +100 °C | Seal: FKM | Communication interface: IO-Link | Output signal: Output 1 (pin 4): PNP/NPN/PP or IO-Link, Output 2 (pin 2): PNP/NPN/PP or analog 4...20 mA, 0...10 V, 1...10 V (each freely scala

EXS-09D6403B020, EXE-09D6403B020
Safety light curtains | deTec | EXS-09D6403B020, EXE-09D6403B020 | Product version: deTec4 Core Ex | System part: Pair | Application: Explosive areas | Ex-approvals: Ex II 2G / 2D, NFPA 70 / NEC 500, classes I, II, III, div. 1 | Safety level: PL e, SIL 3, Type 4 | Resolution: 30 mm | Scanning range: 10 m | Protective field height: 900 mm | Connection type: Connecting cable, 30 m, flying leads, 5-wire | Enclosure rating: IP65, IP66 | Items supplied: Sender in explosion-proof enclosure with connec

SET FORK HOLDER REFLECTOR SD100
Mounting systems | Assembly accessories | SET FORK HOLDER REFLECTOR SD100 | Description: Bracket for reflective foil (scope of delivery of AS30) or accessory reflector. Simple alignment and adjustment of the correct sensing distance. | Material: Steel | Details: Steel, zinc coated | Items supplied: Screw set for AS30, Mounting bracket | Suitable for: AS30

DBS60E-T1ACD1024
Incremental encoders | DBS60 | DBS60E-T1ACD1024 | Mechanical design: Through hollow shaft 6 mm (Front clamp) | Communication interface: 4.5 V ... 5.5 V, TTL, RS-422 | Connection type: Male connector, M12, 8-pin, radial | Pulses per revolution: 1,024 | Flange type / stator coupling: 1-sided stator coupling, slot, screw hole circle radius 31.5–48.5 mm

SLG50S-030SAKA1K01
Automation light grids | FlexChain | SLG50S-030SAKA1K01 | Device version: FlexChain Guest | Optical light exit: Slim | Beam separation: 50 mm | Operating range: 4 m | Detection height: 300 mm | Length of cable: 0.5 m

PBT-RP100SN1SS0V5C0Z
Pressure sensors | PBT | PBT-RP100SN1SS0V5C0Z | Pressure type: Gauge pressure | Pressure unit: psi | Measuring range: 0 psi ... 100 psi | Accuracy: ≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: ¼'' NPT | Pressure port: Standard | Process temperature: 0 °C ... +80 °C | Seal: Without seal | Communication interface: - | Output signal: 0 V ... 10 V, 3-wire | Connection type: F

MLG25N-0725N10501
Automation light grids | MLG-2 | MLG25N-0725N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

LFV200-XATGBCPVL
Level sensors | LFV200 | LFV200-XATGBCPVL | Communication interface: - | Process connection: G ¾ A PN 64 | Probe length: 115 mm | Probe type: Tuning fork | Remote amplifier: No | Output signal: Non-contact switch | Connection type: Valve plug DIN 43650 | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 64 bar | Wetted parts: Stainless steel 1.4404 / 316L | Housing material: Stainless steel 1.4404 / 316L, PEI | Enclosure rating: IP65 | Display: no | PWIS-cleaned: no | Blueto

C4MT-03614ABB03DE0
Safety light curtains | miniTwin | C4MT-03614ABB03DE0 | Usage: miniTwin4 as a standalone device, miniTwin4 as last guest for 2- or 3-device cascade | Mounting system type: C-fix or L-fix bracket | Safety level: PL e, SIL 3, Type 4 | Resolution: 14 mm | Scanning range: 5 m | Protective field height: 360 mm | Connection type: Plug, M12, 5-pin | Enclosure rating: IP65 | Items supplied: Twin stick, system plug, C-Fix and L-Fix bracket, 2 pieces each, test rod with diameter corresponding to the reso

SFS60-HPAT0K02
Motor feedback systems | SFS/SFM60 | SFS60-HPAT0K02 | Communication interface: HIPERFACE® | Model: Absolute Singleturn | Type: Stand-alone | Sine/cosine periods per revolution: 1,024 | Safety system: no | Mechanical design: Through hollow shaft | Connection type: Male connector, M23, 12-pin, radial | Technology: Optical | Operating temperature range: –40 °C ... +115 °C | Items supplied: M3 mounting screws for stator coupling not included with delivery.

BEF-MS12L-S03
Mounting systems | Brackets | BEF-MS12L-S03 | Description: Mounting bar, L-shaped, 100 mm x 250 mm | Material: Steel | Details: Steel, zinc coated

BEF-HA-TCLI20-FTS1
Mounting systems | Flanges and nozzles | BEF-HA-TCLI20-FTS1 | Description: Hygienic process adapter for T-Easic FTS, clamp (DIN 32676), DN 50 (2'') | Material: Stainless steel | Details: Stainless steel 1.4404 / 316L | Usable for: FKM

PBS2-AB2X5SF2FSDNMA0Z
Pressure sensors | PBS plus | PBS2-AB2X5SF2FSDNMA0Z | Pressure type: Absolute pressure | Pressure unit: bar psi | Measuring range: 0 bar ... 2.5 bar, 0 psi ... 36 psi | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: G ½ B flush mounted | Pressure port: Front-flush membrane | Process temperature: –20 °C ... +85 °C | Seal: NBR | Communication interface: IO-Link |