AD1
AD6/CN-1A
Ind.M5,NPN-NC,Cable,Sch-STD
Inductive sensor M5 Sn 0,8 mm NC/NPN cable 2m axial
M5 cylindrical miniaturized inductive sensors
Overview
- Extremely reduced models: M5 x 30 mm (cable) / 38 mm (plug) lenght
- Operating voltage: 10...30 Vcc
- Output current: 100 mA
- LED output indicator
- Totally protected against electrical damages
- Cable and M8 plug output
- Stainless steel housing
Technical Features
Detection properties
Nominal sensing distance | 0,8mm
Operanting distance | 0…0,65mm Standard target | 5x5mm FE360 Correction Factor | copper: 0,32 ± 10% / aluminium: 0,26 ± 10% / brass: 0,35 ± 10% / stainless steel: 0,66 ± 10% Thermal drift of Sr | < 10% Repeat Accuracy | < 5% (UB 24V Ta=23°C ±5°C) Hysteresis | 1 … 20%
Application
Description | M5 short case flush mount
Functions | Proximity
Outputs
Output type | NPN
Output Function | NC Switching frequency | 5kHz
Electrical data
Operating Voltage | 10...30Vdc
No-Load supply current | ≤ 10mA Load current | ≤ 100mA Leakage current | ≤ 10μA Output voltage drop | ≤ 1,5V @100mA Max ripple content | ≤ 10% LED indicators | Yellow LED output state Time delay before availability | ≤ 50ms Short-circuit protection | Yes Reverse Polarity Protection | Yes Impulsive Overvoltage Protection | Yes Protection against inductive loads | Yes
Mechanical data
Dimensions | M5 x 0,5 / L = 24,9mm
Mounting | Shielded Material | AISI303 Stainless Steel Housing material | AISI303 Stainless Steel Weight | 30g Connections | 2m PVC Cable Active Head Material | PBT Tightening torque | 2Nm Operating temperature | -25°C…+70°C Diameter/Dimension | M5
Test/Approvals
Approvals | CE cULus
EMC compatibility | IEC 60947-5-2 Shocks and vibrations | Vibration IEC 60068-2-6 / Shock IEC 60068-2-27 Degree of protection | IP67
Accessories
Supplied Accessories | 2 nuts M5x0.5
Generical Data
Dimensions | M5 x 0,5 / L = 24,9mm
Operating Temperature | -25°C…+70°C Mechanical Protection | IP67
Connections
Eletrical diagram
Others
Dimensions