Серия MLG-2

1562 варианта от SICK. Изберете модела, който отговаря на приложението ви, или попитайте нас.

Показани 961–1008 · страница 21 от 33

MLG25N-0275N10501
1221316

MLG25N-0275N10501

SICK

Automation light grids | MLG-2 | MLG25N-0275N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 275 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0275P10501
1217912

MLG25N-0275P10501

SICK

Automation light grids | MLG-2 | MLG25N-0275P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 275 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0275U10801
1222513

MLG25N-0275U10801

SICK

Automation light grids | MLG-2 | MLG25N-0275U10801 | Device version: ProNet - Replacement product (for MLG-1 with terminals) | Inputs/outputs: RS-485 + 6 x Q + 2 x I/O | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 275 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0425C10501
1116782

MLG25N-0425C10501

SICK

Automation light grids | MLG-2 | MLG25N-0425C10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 425 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0425E10501
1222736

MLG25N-0425E10501

SICK

Automation light grids | MLG-2 | MLG25N-0425E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 425 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0425H10501
1217496

MLG25N-0425H10501

SICK

Automation light grids | MLG-2 | MLG25N-0425H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 425 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0425N10501
1218885

MLG25N-0425N10501

SICK

Automation light grids | MLG-2 | MLG25N-0425N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 425 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0575H10501
1218074

MLG25N-0575H10501

SICK

Automation light grids | MLG-2 | MLG25N-0575H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 575 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0575N10501
1217660

MLG25N-0575N10501

SICK

Automation light grids | MLG-2 | MLG25N-0575N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 575 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0575N10801
1222276

MLG25N-0575N10801

SICK

Automation light grids | MLG-2 | MLG25N-0575N10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 575 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0575P10501
1217913

MLG25N-0575P10501

SICK

Automation light grids | MLG-2 | MLG25N-0575P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 575 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725C10501
1138405

MLG25N-0725C10501

SICK

Automation light grids | MLG-2 | MLG25N-0725C10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725E10501
1220208

MLG25N-0725E10501

SICK

Automation light grids | MLG-2 | MLG25N-0725E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725E10801
1217312

MLG25N-0725E10801

SICK

Automation light grids | MLG-2 | MLG25N-0725E10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725H10501
1216922

MLG25N-0725H10501

SICK

Automation light grids | MLG-2 | MLG25N-0725H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725N10501
1217091

MLG25N-0725N10501

SICK

Automation light grids | MLG-2 | MLG25N-0725N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725P10501
1222206

MLG25N-0725P10501

SICK

Automation light grids | MLG-2 | MLG25N-0725P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0725U10801
1222226

MLG25N-0725U10801

SICK

Automation light grids | MLG-2 | MLG25N-0725U10801 | Device version: ProNet - Replacement product (for MLG-1 with terminals) | Inputs/outputs: RS-485 + 6 x Q + 2 x I/O | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 725 mm | Length of cable: 0.22 m, 0.21 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0875H10501
1220908

MLG25N-0875H10501

SICK

Automation light grids | MLG-2 | MLG25N-0875H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 875 mm | Length of cable: 0.22 m, 0.21 m | Response time: 4.1 ms | Software feature (default setting - see technical data/features): 01

MLG25N-0875N10501
1218046

MLG25N-0875N10501

SICK

Automation light grids | MLG-2 | MLG25N-0875N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 875 mm | Length of cable: 0.22 m, 0.21 m | Response time: 4.1 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1025E10501
1112865

MLG25N-1025E10501

SICK

Automation light grids | MLG-2 | MLG25N-1025E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,025 mm | Length of cable: 0.22 m, 0.21 m | Response time: 4.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1025H10501
1217497

MLG25N-1025H10501

SICK

Automation light grids | MLG-2 | MLG25N-1025H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,025 mm | Length of cable: 0.22 m, 0.21 m | Response time: 4.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1025N10501
1217306

MLG25N-1025N10501

SICK

Automation light grids | MLG-2 | MLG25N-1025N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,025 mm | Length of cable: 0.22 m, 0.21 m | Response time: 4.6 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1175H10501
1218886

MLG25N-1175H10501

SICK

Automation light grids | MLG-2 | MLG25N-1175H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,175 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1175H50501
1149820

MLG25N-1175H50501

SICK

Automation light grids | MLG-2 | MLG25N-1175H50501 | Device version: ProNet – extended functionality including fieldbus | Option: Protective housing IP69K | Beam separation: 25 mm | Operating range: 3.75 m | Detection height: 1,175 mm | Length of cable: 1.4 m, 1.4 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1175N10501
1217661

MLG25N-1175N10501

SICK

Automation light grids | MLG-2 | MLG25N-1175N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,175 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1175N10801
1219100

MLG25N-1175N10801

SICK

Automation light grids | MLG-2 | MLG25N-1175N10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 1,175 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1175U10501
1140164

MLG25N-1175U10501

SICK

Automation light grids | MLG-2 | MLG25N-1175U10501 | Device version: ProNet - Replacement product (for MLG-1 with terminals) | Inputs/outputs: RS-485 + 6 x Q + 2 x I/O | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,175 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1325E10501
1107074

MLG25N-1325E10501

SICK

Automation light grids | MLG-2 | MLG25N-1325E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,325 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1325H10501
1112006

MLG25N-1325H10501

SICK

Automation light grids | MLG-2 | MLG25N-1325H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,325 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1325N10501
1217307

MLG25N-1325N10501

SICK

Automation light grids | MLG-2 | MLG25N-1325N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,325 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1325N10801
1218657

MLG25N-1325N10801

SICK

Automation light grids | MLG-2 | MLG25N-1325N10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 1,325 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.5 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475C10501
1137702

MLG25N-1475C10501

SICK

Automation light grids | MLG-2 | MLG25N-1475C10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475E10501
1221955

MLG25N-1475E10501

SICK

Automation light grids | MLG-2 | MLG25N-1475E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475H10501
1217476

MLG25N-1475H10501

SICK

Automation light grids | MLG-2 | MLG25N-1475H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475H10801
1220014

MLG25N-1475H10801

SICK

Automation light grids | MLG-2 | MLG25N-1475H10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475N10501
1216833

MLG25N-1475N10501

SICK

Automation light grids | MLG-2 | MLG25N-1475N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475N10801
1222672

MLG25N-1475N10801

SICK

Automation light grids | MLG-2 | MLG25N-1475N10801 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1475P10501
1222207

MLG25N-1475P10501

SICK

Automation light grids | MLG-2 | MLG25N-1475P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,475 mm | Length of cable: 0.22 m, 0.21 m | Response time: 5.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625E10501
1217343

MLG25N-1625E10501

SICK

Automation light grids | MLG-2 | MLG25N-1625E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,625 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625H10501
1112618

MLG25N-1625H10501

SICK

Automation light grids | MLG-2 | MLG25N-1625H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,625 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625H50501
1127448

MLG25N-1625H50501

SICK

Automation light grids | MLG-2 | MLG25N-1625H50501 | Device version: ProNet – extended functionality including fieldbus | Option: Protective housing IP69K | Beam separation: 25 mm | Operating range: 3.75 m | Detection height: 1,625 mm | Length of cable: 1.4 m, 1.4 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625N10501
1217616

MLG25N-1625N10501

SICK

Automation light grids | MLG-2 | MLG25N-1625N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,625 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625P10501
1117411

MLG25N-1625P10501

SICK

Automation light grids | MLG-2 | MLG25N-1625P10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,625 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1625U10801
1222514

MLG25N-1625U10801

SICK

Automation light grids | MLG-2 | MLG25N-1625U10801 | Device version: ProNet - Replacement product (for MLG-1 with terminals) | Inputs/outputs: RS-485 + 6 x Q + 2 x I/O | Option: None | Beam separation: 25 mm | Operating range: 8.5 m | Detection height: 1,625 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.4 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1775E10501
1221819

MLG25N-1775E10501

SICK

Automation light grids | MLG-2 | MLG25N-1775E10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,775 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1775H10501
1218993

MLG25N-1775H10501

SICK

Automation light grids | MLG-2 | MLG25N-1775H10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,775 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.9 ms | Software feature (default setting - see technical data/features): 01

MLG25N-1775N10501
1218854

MLG25N-1775N10501

SICK

Automation light grids | MLG-2 | MLG25N-1775N10501 | Device version: ProNet – extended functionality including fieldbus | Option: None | Beam separation: 25 mm | Operating range: 5 m | Detection height: 1,775 mm | Length of cable: 0.22 m, 0.21 m | Response time: 6.9 ms | Software feature (default setting - see technical data/features): 01