Серия MLG-2 WebChecker
269 варианта от SICK. Изберете модела, който отговаря на приложението ви, или попитайте нас.
Показани 145–192 · страница 4 от 6

MLG05W-0454G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0454G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,945 mm | Measuring field width detail (connection side/medium range/head side): 595 mm / 755 mm / 595 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 48.5 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0464B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0464B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,095 mm | Measuring field width detail (connection side/medium range/head side): 595 mm / 905 mm / 595 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 48.5 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0481B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0481B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,945 mm | Measuring field width detail (connection side/medium range/head side): 595 mm / 1,205 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0484N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0484N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,395 mm | Measuring field width detail (connection side/medium range/head side): 595 mm / 1,205 mm / 595 mm | Length of cable: 0.22 m, 0.27 m | Response time: 48.5 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500E12503
Automation light grids | MLG-2 WebChecker | MLG05W-0500E12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0500G12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500G12501 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0500H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0500I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500N12502
Automation light grids | MLG-2 WebChecker | MLG05W-0500N12502 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 02

MLG05W-0500N12503
Automation light grids | MLG-2 WebChecker | MLG05W-0500N12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0500R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0500R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0500R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0500R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0515N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0515N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 155 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0515N52501
Automation light grids | MLG-2 WebChecker | MLG05W-0515N52501 | Device version: Web guiding | Option: Protective housing IP69K | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 155 mm / 745 mm | Length of cable: 1.4 m, 1.4 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0521H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0521H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,195 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 305 mm / 145 mm | Length of cable: 0.22 m, 0.27 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0521R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0521R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,195 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 305 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0525H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0525H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,795 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 305 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0525I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0525I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,795 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 305 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0535B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0535B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,945 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 455 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0535E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0535E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,945 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 455 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0535H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0535H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,945 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 455 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0555E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0555E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 755 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0555G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0555G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 755 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0575B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0575B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 1,055 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0575G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0575G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 1,055 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0575N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0575N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 1,055 mm / 745 mm | Length of cable: 0.22 m, 0.27 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0585G12501
Automation light grids | MLG-2 WebChecker | MLG05W-0585G12501 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,695 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 1,205 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-05B5G12501
Automation light grids | MLG-2 WebChecker | MLG05W-05B5G12501 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 3,145 mm | Measuring field width detail (connection side/medium range/head side): 745 mm / 1,655 mm / 745 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 60.3 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0600B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0600G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0600H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0600H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0600H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0600I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0600I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0600N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600N12503
Automation light grids | MLG-2 WebChecker | MLG05W-0600N12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0600R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0600R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0600R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0600R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 36.7 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0636B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0636B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 455 mm / 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0636H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0636H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 455 mm / 895 mm | Length of cable: 0.22 m, 0.27 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0636I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0636I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 455 mm / 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0636N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0636N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,245 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 455 mm / 895 mm | Length of cable: 0.22 m, 0.27 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0656B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0656B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 755 mm / 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0656E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0656E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 755 mm / 895 mm | Length of cable: 0.22 m, 0.27 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0656G12501
Automation light grids | MLG-2 WebChecker | MLG05W-0656G12501 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 895 mm / 755 mm / 895 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 72.2 ms | Software feature (default setting - see technical data/features): 01