MLG05W-0100B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0100B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100B12599
Automation light grids | MLG-2 WebChecker | MLG05W-0100B12599 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0100E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0100E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0100G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0100H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0100H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0100H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0100I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0100I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0100N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100N12503
Automation light grids | MLG-2 WebChecker | MLG05W-0100N12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0100N52501
Automation light grids | MLG-2 WebChecker | MLG05W-0100N52501 | Device version: Web guiding | Option: Protective housing IP69K | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 1.4 m, 1.4 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0100R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0100R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 145 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 7.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0111B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0111B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 445 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 155 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0111E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0111E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 445 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 155 mm / 145 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-011FR12501
Automation light grids | MLG-2 WebChecker | MLG05W-011FR12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 155 mm / 2,245 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 95.8 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0131R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0131R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 455 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0137N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0137N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 455 mm / 1,045 mm | Length of cable: 0.22 m, 0.27 m | Response time: 48.5 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0151N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0151N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,045 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 755 mm / 145 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0162I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0162I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,345 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 905 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 19 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0171B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0171B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,345 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 1,055 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0191B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0191B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 1,355 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0191I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0191I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 1,355 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0191N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0191N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 1,355 mm / 145 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-01F1B12501
Automation light grids | MLG-2 WebChecker | MLG05W-01F1B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 2,545 mm | Measuring field width detail (connection side/medium range/head side): 145 mm / 2,255 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200E12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200E12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200E12502
Automation light grids | MLG-2 WebChecker | MLG05W-0200E12502 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 02

MLG05W-0200E12503
Automation light grids | MLG-2 WebChecker | MLG05W-0200E12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0200G12599
Automation light grids | MLG-2 WebChecker | MLG05W-0200G12599 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 99

MLG05W-0200H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0200H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0200H52501
Automation light grids | MLG-2 WebChecker | MLG05W-0200H52501 | Device version: Web guiding | Option: Protective housing IP69K | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 1.4 m, 1.4 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200I12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200I12501 | Device version: Web guiding | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200N12503
Automation light grids | MLG-2 WebChecker | MLG05W-0200N12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0200R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0200R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0200R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0200R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 295 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 0 mm / 0 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 13.1 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0212B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0212B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 155 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0212N12501
Automation light grids | MLG-2 WebChecker | MLG05W-0212N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 155 mm / 295 mm | Length of cable: 0.22 m, 0.27 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0212R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0212R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 745 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 155 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0222B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0222B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 305 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0222H12501
Automation light grids | MLG-2 WebChecker | MLG05W-0222H12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 305 mm / 295 mm | Length of cable: 0.22 m, 0.27 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0222H12503
Automation light grids | MLG-2 WebChecker | MLG05W-0222H12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 305 mm / 295 mm | Length of cable: 0.22 m, 0.27 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0222R12501
Automation light grids | MLG-2 WebChecker | MLG05W-0222R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 305 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0222R12503
Automation light grids | MLG-2 WebChecker | MLG05W-0222R12503 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 895 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 305 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 03

MLG05W-0232G12501
Automation light grids | MLG-2 WebChecker | MLG05W-0232G12501 | Device version: Web guiding | Inputs/outputs: 1 x analog + 3 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,045 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 455 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0236H52501
Automation light grids | MLG-2 WebChecker | MLG05W-0236H52501 | Device version: Web guiding | Option: Protective housing IP69K | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,645 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 455 mm / 895 mm | Length of cable: 1.4 m, 1.4 m | Response time: 48.5 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0242B12501
Automation light grids | MLG-2 WebChecker | MLG05W-0242B12501 | Device version: Web guiding | Inputs/outputs: 2 x analog + 2 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,195 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 605 mm / 295 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 01

MLG05W-0242N12503
Automation light grids | MLG-2 WebChecker | MLG05W-0242N12503 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,195 mm | Measuring field width detail (connection side/medium range/head side): 295 mm / 605 mm / 295 mm | Length of cable: 0.22 m, 0.27 m | Response time: 24.9 ms | Software feature (default setting - see technical data/features): 03