Серия i110 Lock

10 варианта от SICK. Изберете модела, който отговаря на приложението ви, или попитайте нас.

i110-E0233
6051597

i110-E0233

SICK

Safety switches | i110 Lock | i110-E0233 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 1 | Positive action N/C door monitoring contacts: 0

i110-E0253
6051599

i110-E0253

SICK

Safety switches | i110 Lock | i110-E0253 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 0

i110-E0313S06
6035038

i110-E0313S06

SICK

Safety switches | i110 Lock | i110-E0313S06 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 1

i110-E0354
6053945

i110-E0354

SICK

Safety switches | i110 Lock | i110-E0354 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Plug connector, M12, 8-pin | Safe series connection: With Flexi Loop (with diagnostics) | Positive action N/C solenoid monitoring contacts: 1 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 2

i110-E0453
6051601

i110-E0453

SICK

Safety switches | i110 Lock | i110-E0453 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 2

i110-E0454
6051603

i110-E0454

SICK

Safety switches | i110 Lock | i110-E0454 | Locking principle: Power to lock | Locking force FZh: 2,000 N | Connection type Detail: Plug connector, M12, 8-pin | Safe series connection: With Flexi Loop (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 1

i110-M0233
6051596

i110-M0233

SICK

Safety switches | i110 Lock | i110-M0233 | Locking principle: Power to release | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 1 | Positive action N/C door monitoring contacts: 0

i110-M0253
6051598

i110-M0253

SICK

Safety switches | i110 Lock | i110-M0253 | Locking principle: Power to release | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 0

i110-M0453
6051600

i110-M0453

SICK

Safety switches | i110 Lock | i110-M0453 | Locking principle: Power to release | Locking force FZh: 2,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 2

i110-M0454
6051602

i110-M0454

SICK

Safety switches | i110 Lock | i110-M0454 | Locking principle: Power to release | Locking force FZh: 2,000 N | Connection type Detail: Plug connector, M12, 8-pin | Safe series connection: With Flexi Loop (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 1