Серия Dx50

22 варианта от SICK. Изберете модела, който отговаря на приложението ви, или попитайте нас.

DL50-N1123
1047401

DL50-N1123

SICK

Laser distance sensors | Dx50 | DL50-N1123 | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x NPN | Type of analog output: Current output | Multifunctional input (MF): 1 x

DL50-N2225
1048419

DL50-N2225

SICK

Laser distance sensors | Dx50 | DL50-N2225 | Communication interface: Serial | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 1 ... 2 x NPN | Multifunctional input (MF): − / 1 x

DL50-N2228
1058987

DL50-N2228

SICK

Laser distance sensors | Dx50 | DL50-N2228 | Communication interface: SSI | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 1 ... 2 x NPN | Multifunctional input (MF): − / 1 x

DL50-P1123
1047361

DL50-P1123

SICK

Laser distance sensors | Dx50 | DL50-P1123 | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x PNP | Type of analog output: Current output | Multifunctional input (MF): 1 x

DL50-P2225
1048418

DL50-P2225

SICK

Laser distance sensors | Dx50 | DL50-P2225 | Communication interface: Serial | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 1 ... 2 x PNP | Multifunctional input (MF): − / 1 x

DL50-P2228
1058986

DL50-P2228

SICK

Laser distance sensors | Dx50 | DL50-P2228 | Communication interface: SSI | Measuring range: 200 mm ... 50,000 mm, on “diamond grade” reflective tape | Laser class: 1 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 1 ... 2 x PNP | Multifunctional input (MF): − / 1 x

DS50-N1112
1047404

DS50-N1112

SICK

Laser distance sensors | Dx50 | DS50-N1112 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,000 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 2 x NPN | Multifunctional input (MF): 1 x

DS50-N1122
1047406

DS50-N1122

SICK

Laser distance sensors | Dx50 | DS50-N1122 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,000 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 2 x NPN | Multifunctional input (MF): 1 x

DS50-P1112
1047402

DS50-P1112

SICK

Laser distance sensors | Dx50 | DS50-P1112 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,000 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 10 ms | Digital output: 2 x PNP | Multifunctional input (MF): 1 x

DS50-P1122
1047405

DS50-P1122

SICK

Laser distance sensors | Dx50 | DS50-P1122 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,000 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 2 x PNP | Multifunctional input (MF): 1 x

DT50-N1113
1047396

DT50-N1113

SICK

Laser distance sensors | Dx50 | DT50-N1113 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,500 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x NPN | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-N1114
1047582

DT50-N1114

SICK

Laser distance sensors | Dx50 | DT50-N1114 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,500 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x NPN | Type of analog output: Voltage output | Multifunctional input (MF): 1 x

DT50-N1123
1047397

DT50-N1123

SICK

Laser distance sensors | Dx50 | DT50-N1123 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 5,000 mm, 18% remission factor, 200 mm ... 2,500 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x NPN | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-N1124
1047617

DT50-N1124

SICK

Laser distance sensors | Dx50 | DT50-N1124 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 5,000 mm, 18% remission factor, 200 mm ... 2,500 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x NPN | Type of analog output: Voltage output | Multifunctional input (MF): 1 x

DT50-N2113
1047398

DT50-N2113

SICK

Laser distance sensors | Dx50 | DT50-N2113 | Measuring range: 200 mm ... 20,000 mm, 90% remission factor, 200 mm ... 8,500 mm, 18% remission factor, 200 mm ... 5,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x NPN | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-N2123
1047400

DT50-N2123

SICK

Laser distance sensors | Dx50 | DT50-N2123 | Measuring range: 200 mm ... 13,000 mm, 90% remission factor, 200 mm ... 5,800 mm, 18% remission factor, 200 mm ... 3,400 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x NPN | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-P1113
1044369

DT50-P1113

SICK

Laser distance sensors | Dx50 | DT50-P1113 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,500 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x PNP | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-P1114
1047581

DT50-P1114

SICK

Laser distance sensors | Dx50 | DT50-P1114 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 6,500 mm, 18% remission factor, 200 mm ... 4,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x PNP | Type of analog output: Voltage output | Multifunctional input (MF): 1 x

DT50-P1123
1047118

DT50-P1123

SICK

Laser distance sensors | Dx50 | DT50-P1123 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 5,000 mm, 18% remission factor, 200 mm ... 2,500 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x PNP | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-P1124
1047616

DT50-P1124

SICK

Laser distance sensors | Dx50 | DT50-P1124 | Measuring range: 200 mm ... 10,000 mm, 90% remission factor, 200 mm ... 5,000 mm, 18% remission factor, 200 mm ... 2,500 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 20 ms | Digital output: 1 x PNP | Type of analog output: Voltage output | Multifunctional input (MF): 1 x

DT50-P2113
1047314

DT50-P2113

SICK

Laser distance sensors | Dx50 | DT50-P2113 | Measuring range: 200 mm ... 20,000 mm, 90% remission factor, 200 mm ... 8,500 mm, 18% remission factor, 200 mm ... 5,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x PNP | Type of analog output: Current output | Multifunctional input (MF): 1 x

DT50-P2123
1047399

DT50-P2123

SICK

Laser distance sensors | Dx50 | DT50-P2123 | Measuring range: 200 mm ... 13,000 mm, 90% remission factor, 200 mm ... 5,800 mm, 18% remission factor, 200 mm ... 3,400 mm, 6% remission factor | Laser class: 1 | Light source: Laser, red | Minimum response time: 15 ms | Digital output: 1 x PNP | Type of analog output: Current output | Multifunctional input (MF): 1 x